Abstract
A stability study of distribution networks with a high penetration of distributed generators (DGs) actively supporting the network is presented in this paper. A possible way of mitigating the voltage rise caused by DGs is the local control of reactive power. Among the different possible options, the Q(U) control (reactive power as a function of the voltage) is one of the commonly suggested solutions. However, the Q(U) control can, under certain conditions, lead to instability. This paper summarizes the results of a stability study conducted on a single-inverter system and on a multiinverter system. It shows that the requirements for reaching a stable operation can easily be met for integrated systems but could be a significant constraint for systems relying on communication.Keywords
This publication has 23 references indexed in Scilit:
- Optimal Decentralized Voltage Control for Distribution Systems With Inverter-Based Distributed GeneratorsIEEE Transactions on Power Systems, 2013
- An Intelligent Droop Control for Simultaneous Voltage and Frequency Regulation in Islanded MicrogridsIEEE Transactions on Smart Grid, 2013
- Voltage Support Control Strategies for Static Synchronous Compensators Under Unbalanced Voltage SagsIEEE Transactions on Industrial Electronics, 2013
- Online Reconfigurable Control Software for IEDsIEEE Transactions on Industrial Informatics, 2013
- Improved Low Voltage Grid-Integration of Photovoltaic Systems in GermanyIEEE Transactions on Sustainable Energy, 2012
- Harmonic Droop Controller to Reduce the Voltage Harmonics of InvertersIEEE Transactions on Industrial Electronics, 2012
- Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid FaultIEEE Transactions on Industrial Electronics, 2012
- Online Optimal Reactive Power Control Strategy of PV InvertersIEEE Transactions on Industrial Electronics, 2011
- Hierarchical Control of Intelligent MicrogridsIEEE Industrial Electronics Magazine, 2010
- Second-Order SM Approach to SISO Time-Delay System Output TrackingIEEE Transactions on Industrial Electronics, 2009