EEATC: A Novel Calibration Approach for Low-cost Sensors
Authors:
- M V NarayanaMNM V Narayana
- Devendra JalihalDJDevendra Jalihal
- Shiva NagendraSNShiva Nagendra
Preprint
Abstract
Low-cost sensors (LCS) are affordable, compact, and often portable devices designed to measure various environmental parameters, including air quality. These sensors are intended to provide accessible and cost-effective solutions for monitoring pollution levels in different settings, such as indoor, outdoor and moving vehicles. However, the data produced by LCS is prone to various sources of error that can affect accuracy. Calibration is a well-known procedure to improve the reliability of the data produced by LCS, and several developments and efforts have been made to calibrate the LCS. This work proposes a novel Estimated Error Augmented Two-phase Calibration (\textit{EEATC}) approach to calibrate the LCS in stationary and mobile deployments. In contrast to the existing approaches, the \textit{EEATC} calibrates the LCS in two phases, where the error estimated in the first phase calibration is augmented with the input to the second phase, which helps the second phase to learn the distributional features better to produce more accurate results. We show that the \textit{EEATC} outperforms well-known single-phase calibration models such as linear regression models (single variable linear regression (SLR) and multiple variable linear regression (MLR)) and Random forest (RF) in stationary and mobile deployments. To test the \textit{EEATC} in stationary deployments, we have used the Community Air Sensor Network (CAIRSENSE) data set approved by the United States Environmental Protection Agency (USEPA), and the mobile deployments are tested with the real-time data obtained from SensurAir, an LCS device developed and deployed on moving vehicle in Chennai, India.Keywords
All Related Versions
- Version 1, 2023-08-25, ArXiv
- Published version: IEEE Sensors Journal, 23 (19), 23500.
This publication has 51 references indexed in Scilit:
- Design, calibration, and testing of a mobile sensor system for air pollution and built environment data collection: The urban scanner platformEnvironmental Pollution, 2022
- Calibration of a low-cost PM2.5 monitor using a random forest modelEnvironment International, 2019
- Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring siteAtmospheric Environment, 2019
- Development of a calibration chamber to evaluate the performance of low-cost particulate matter sensorsEnvironmental Pollution, 2019
- Calibration of low-cost NO2 sensors in an urban air quality networkAtmospheric Environment, 2019
- Regression methods in the calibration of low-cost sensors for ambient particulate matter measurementsSN Applied Sciences, 2019
- Analysing the performance of low-cost air quality sensors, their drivers, relative benefits and calibration in cities—a case study in SheffieldEnvironmental Monitoring and Assessment, 2019
- Development of a baseline-temperature correction methodology for electrochemical sensors and its implications for long-term stabilityAtmospheric Environment, 2016
- Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxideAtmospheric Environment, 2015
- On the equivalence of gravimetric PM data with TEOM and beta-attenuation measurementsJournal of Aerosol Science, 2004