Minimally Invasive Surgery (MIS) evolved as an alternative to open surgical approaches, and resulted in reduced surgical trauma and faster recovery. However, the confined workspace, loss of depth perception, compromised hand-eye coordination, as well as extended learning curves precluded the surgeons from adapting this approach in all cases. Unlike rigid robots that are characterized with mechanical rigidity and limited degrees-of-freedom (DOFs), continuum robots were developed mainly for interventional medicine. A special class of continuum robots are Concentric Tube Robots (CTRs), that have diameters comparable to those of catheters and steerable needles. Since their introduction, huge effort has been dedicated to the kinematic modelling and real-time control. Due to their intrinsic actuation capability, miniaturization potential and controllable mechanical properties, they have been adopted for different surgical applications. Experimental tests based on phantom and cadaveric studies were performed to prove their feasibility. This review encompasses the generic design, modelling and control methods of CTRs. It also addresses, in detail, their different surgical applications. Finally, related main research limitations and future opportunities are briefly discussed.Keywords
Funding Information
- Khalifa University of Science and Technology [Healthcare Engineering Innovation Center (HEIC)] (RC2-2018-022)
This publication has 143 references indexed in Scilit:
- Modeling, Force Sensing, and Control of Flexible Cannulas for Microstent DeliveryJournal of Dynamic Systems, Measurement, and Control, 2012
- Robotic Surgery in Otolaryngology and Head and Neck Surgery: A ReviewMinimally Invasive Surgery, 2012
- Advanced stereoscopic projection technology significantly improves novice performance of minimally invasive surgical skillsSurgical Endoscopy, 2012
- Design and Kinematic Modeling of Constant Curvature Continuum Robots: A ReviewThe International Journal of Robotics Research, 2010
- Equilibrium Conformations of Concentric-tube Continuum RobotsThe International Journal of Robotics Research, 2010
- Robotic Motion Compensation for Beating Heart Intracardiac SurgeryThe International Journal of Robotics Research, 2009
- Curved multi‐tube device for path‐error correction in a needle‐insertion systemThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Hand-Held Steerable Needle DeviceIEEE/ASME Transactions on Mechatronics, 2005
- Kinematics and the Implementation of an Elephant's Trunk Manipulator and Other Continuum Style RobotsJournal of Robotic Systems, 2003
- THE DEVELOPMENT OF THE CYSTOSCOPEJournal of Urology, 1998