Dynamic and simultaneous MR measurement of R1 and R2* changes during respiratory challenges for the assessment of blood and tissue oxygenation
Open Access
- 24 August 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (1) , 136-146
Abstract
This work presents a novel method for the rapid and simultaneous measurement of R1 and R2* relaxation rates. It is based on a dynamic short repetition time steady‐state spoiled multigradient‐echo sequence and baseline R1 and B1 measurements. The accuracy of the approach was evaluated in simulations and a phantom experiment. The sensitivity and specificity of the method were demonstrated in one volunteer and in four patients with intracranial tumors during carbogen inhalation. We utilized (ΔR2*, ΔR1) scatter plots to analyze the multiparametric response amplitude of each voxel within an area of interest. In normal tissue R2* decreased and R1 increased moderately in response to the elevated blood and tissue oxygenation. A strong negative ΔR2* and ΔR1 response was observed in veins and some tumor areas. Moderate positive ΔR2* and ΔR1 response amplitudes were found in fluid‐rich tissue as in cerebrospinal fluid, peritumoral edema, and necrotic areas. The multiparametric approach was shown to increase the specificity and sensitivity of oxygen‐enhanced MRI compared to measuring ΔR2* or ΔR1 alone. It is thus expected to provide an optimal tool for the identification of tissue areas with low oxygenation, e.g., in tumors with compromised oxygen supply. Magn Reson Med, 2013.Keywords
This publication has 40 references indexed in Scilit:
- Is T2* Enough to Assess Oxygenation? Quantitative Blood Oxygen Level–Dependent Analysis in Brain TumorRadiology, 2012
- Quantitative MRI assessment of VX2 tumour oxygenation changes in response to hyperoxia and hypercapniaPhysics in Medicine & Biology, 2011
- Changes in the MR relaxation rate R2* induced by respiratory challenges at 3.0 T: a comparison of two quantification methodsNMR in Biomedicine, 2010
- Quantification of the magnetic resonance signal response to dynamic (C)O2‐enhanced imaging in the brain at 3 T: R*2 BOLD vs. balanced SSFPJournal of Magnetic Resonance Imaging, 2010
- MR signal response to hyperoxic and hypercapnic respiratory challenges in the brain at 3 TRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2009
- Human cerebrovascular and ventilatory CO2 reactivity to end‐tidal, arterial and internal jugular vein PCO2The Journal of Physiology, 2007
- Structural, Functional, and Molecular MR Imaging of the MicrovasculatureAnnual Review of Biomedical Engineering, 2003
- How does blood oxygen level‐dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors?Magnetic Resonance in Medicine, 2002
- RLSQ: T1, T2, and ρ calculations, combining ratios and least squaresMagnetic Resonance in Medicine, 1987
- Enhancement of relaxation rate with paramagnetic contrast agents in NMR imagingJournal of Computed Tomography, 1981