A New Sensitivity-Improving Method for Piezoelectric Resonance Mass Sensors Through Cantilever Cross-Section Modification
Authors:
- 16 April 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (3) , 1612-1621
Abstract
Resonant cantilever sensors have been extensively used in mass detection applications. In this paper, a new sensitivity-improving method was proposed by modifying the cross-section shape of the cantilever. With the same dimension, the proposed sensor can offer two to eight times greater sensitivity than traditional rectangular section cantilever sensors. To eliminate the size effect, a dimensionless mathematical model was established for examining the sensitivity improvement brought by adding axial grooves to elastic structures. By utilizing wire-cutting technology, a novel grooved-section cantilever sensor was designed and fabricated, which is comprised of one lead zirconate titanate layer bonding to the grooved cantilever for self-exciting and self-sensing. Experimental results show that the sensitivity of the grooved-cantilever sensor is 37.5 kHz/g with the theoretical sensitivity of 38.1 kHz/g, which is about 120% greater than that of the rectangular section sensor of 17.9 kHz/g with the theoretical sensitivity of 18.2 kHz/g. Thus, the comparison validated the effectiveness of the sensitivity-improving method within the same geometric dimension. Furthermore, by optimizing both the cross-section shape and the geometrical ratios of the elastic extension to the piezoelectric layer simultaneously, the overall sensitivity can be increased by 8.15 times greater than that of the rectangular section cantilever sensor, which has great potential applications in high-resolution mass sensors.Keywords
This publication has 46 references indexed in Scilit:
- Piezoelectric cantilever sensors with asymmetric anchor exhibit picogram sensitivity in liquidsSensors and Actuators B: Chemical, 2011
- Preliminary Study of Resonant Mass Sensors Based on Asymmetrically Gapped CantileversIEEE Sensors Journal, 2010
- Enhanced sensitivity of mass detection using the first torsional mode of microcantileversMeasurement Science and Technology, 2008
- Flexural Vibrations and Resonance of Piezoelectric Cantilevers with a Nonpiezoelectric ExtensionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007
- Label-free protein assay with site-directly immobilized antibody using self-actuating PZT cantileverSensors and Actuators B: Chemical, 2006
- Mass detection sensitivity of piezoelectric cantilevers with a nonpiezoelectric extensionReview of Scientific Instruments, 2006
- In situ cell detection using piezoelectric lead zirconate titanate-stainless steel cantileversJournal of Applied Physics, 2003
- Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantileversJournal of Applied Physics, 2002
- Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantileversJournal of Applied Physics, 2001
- Electromechanical Behavior of PZT‐Brass UnimorphsJournal of the American Ceramic Society, 1999