Data‐Driven Characterization of Knee Structures Using Non‐Negative Matrix Factorization of 3D Multi‐Echo UTE MRI
Open Access
- 7 May 2026
- journal article
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (6) , e70299
Abstract
T 2 * quantification based on multi‐echo ultrashort echo time (UTE) MRI has been widely proposed for knee tissue characterization, yet accurate model‐based parameter estimation remains challenging due to ill‐conditioning of the corresponding inverse problems. Alternatively, data‐driven methods such as non‐negative matrix factorization (NMF) can derive tissue features without relying on biophysical model assumptions. This study aimed to investigate the use of an NMF‐based framework informed by 3D multi‐echo UTE MRI for multi‐compartmental analysis of healthy and impaired knee structures. To this end, six asymptomatic adults and 13 patients underwent 3‐T MRI, including routine anatomical sequences, and a 3D UTE spiral research sequence with six echo times. Convexity‐constrained NMF was used to identify characteristic signal components from UTE T 2 *‐weighted datasets. Basis functions were determined based on asymptomatic knee data and used to compute subject‐specific weight maps. Normalized weight distributions were computed for 13 regions of interest across asymptomatic knees and contrasted with median weights of selected structures in patients. The application of the NMF‐based framework yielded four reproducible basis functions associated with fast decay, slow decay, water–fat mixing, and fat‐like behavior. Knee structures with known short T 2 * showed a dominant fast‐decaying component (median weights ≥ 0.68), while structures with long T 2 * showed a greater contribution from the slowly‐decaying component (median weights ≥ 0.44). The fat‐like component was predominant in Hoffa's fat pad, while the water–fat mixture‐related component's contribution was overall low. Lesioned menisci and ligaments generally displayed reduced fast‐decaying and increased slowly decaying component contributions. These findings suggest that convexity‐constrained NMF of 3D multi‐echo UTE MRI is feasible for data‐driven knee tissue characterization as it extracts biophysically related signal components and describes their relative contribution to the measured signal in various knee tissues. Moreover, the proposed framework shows potential for differentiation between asymptomatic and impaired knee tissues, particularly in the posterior horn of the medial meniscus and the anterior cruciate ligament, and consequently holds promise for more objective diagnosis and monitoring of internal knee derangements.Keywords
Funding Information
- Universiteit Antwerpen (44883)
- HORIZON EUROPE Framework Programme (101126235)
This publication has 55 references indexed in Scilit:
- UTE imaging in the musculoskeletal systemJournal of Magnetic Resonance Imaging, 2014
- Quantitative MRI analysis of menisci using biexponential T2* fitting with a variable echo time sequenceMagnetic Resonance in Medicine, 2013
- Repeatability of ultrashort echo time‐based two‐component T2* measurements on cartilages in human knee at 3 TMagnetic Resonance in Medicine, 2012
- UTE-T2∗ mapping detects sub-clinical meniscus injury after anterior cruciate ligament tearOsteoarthritis and Cartilage, 2012
- Investigations of the origin of phase differences seen with ultrashort TE imaging of short T2 meniscal tissueMagnetic Resonance in Medicine, 2011
- N4ITK: Improved N3 Bias CorrectionIEEE Transactions on Medical Imaging, 2010
- Convex and Semi-Nonnegative Matrix FactorizationsIEEE Transactions on Pattern Analysis and Machine Intelligence, 2008
- Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imagingMagnetic Resonance in Medicine, 2008
- The magic angle effect: A source of artifact, determinant of image contrast, and technique for imagingJournal of Magnetic Resonance Imaging, 2007
- Learning the parts of objects by non-negative matrix factorizationNature, 1999