Stability of Built-Up Timber Beams and Columns: Accounting for Modulus of Elasticity Variability
- 1 November 2010
- journal article
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 15 (4) , 272-277
Abstract
Built-up beams and columns comprised of dimension lumber fastened with nails, bolts or lag screws, are common in construction. Current design practice for stability checks is to use the lower-tail modulus of elasticity value tabulated for dimension lumber; however, this ignores the averaging effect on that occurs when the mechanically fastened laminations are constrained to deflect in unison. In this paper, we propose a method for checking stability of these assemblies that is based on established statistical theory. A factor is proposed to adjust value used in column and beam stability calculations to account for the reduced variability of when the laminations are constrained to deflect together. Using to account for the reduction of variability produces more efficient designs with respect to stability. Two examples are provided and each results in larger design capacities compared to current design methods for built-up beams and columns.
Keywords
This publication has 1 reference indexed in Scilit:
- Impact of Permanent Diagonal Bracing on Different MPC Wood Truss TypesPractice Periodical on Structural Design and Construction, 1999