Effective Taper Criterion for the Full Veneer Crown Preparation in Preclinical Prosthodontics

Authors:
  • JGJohn J. Gary
    John J. Gary
  • JCJ. Elaine Conkin
    J. Elaine Conkin

Abstract
Purpose: Effective taper criteria must define a realistic, measurable goal that the student can visualize and achieve. Six degrees is widely accepted as the taper criterion for the full veneer crown preparation. However, studies show the actual taper of most preparations to be greater than 12°. The purpose of this study was to determine whether 12° is an effective taper criterion for the full veneer crown preparation in preclinical prosthodontics instruction.Materials and Methods: A group of 191 full veneer crown preparations with 6° as the taper criterion, and a group of 130 full veneer crown preparations with 12° as the taper criterion were evaluated. All preparations were accomplished by preclinical dental students working on typodonts under examination conditions.Results: The overall mean taper for each group exceeded the targeted criterion. The overall mean taper for the 6° group was 14.490. When 12° was the criterion, the overall mean taper was 15.580. The t test results indicate significant differences (p < .0001) between the targeted criterion and the actual preparation mean taper in all samples except one: the faciolingual measurements in the 12° group. The faciolingual measurement of 12.920 was not statistically significantly different (.0542) from the targeted criterion of 12°.Conclusion: The use of a 12° taper criterion did not result in preclinical students achieving the goal of a 12° taper. However, a 12° criterion is more realistic than a 6° criterion for full veneer crown preparations.

This publication has 18 references indexed in Scilit: