A Simple Low-Dose X-Ray CT Simulation From High-Dose Scan
- 23 September 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (5) , 2226-2233
Abstract
Low-dose X-ray computed tomography (CT) simulation from a high-dose scan is required in optimizing radiation dose to patients. In this paper, we propose a simple low-dose CT simulation strategy in the sinogram domain using the raw data from high-dose scan. Specially, a relationship between the incident fluxes of low- and high-dose scans is first determined according to the repeated projection measurements and analysis. Second, the incident flux level of the simulated low-dose scan is generated by properly scaling the incident flux level of the high-dose scan via the determined relationship in the first step. Third, the low-dose CT transmission data by energy integrating detection is simulated by adding a statistically independent Poisson noise distribution plus a statistically independent Gaussian noise distribution. Finally, a filtered back-projection (FBP) algorithm is implemented to reconstruct the resultant low-dose CT images. The present low-dose simulation strategy is verified on the simulations and real scans by comparing it with the existing low-dose CT simulation tool. Experimental results demonstrated that the present low-dose CT simulation strategy can generate accurate low-dose CT sinogram data from high-dose scans in terms of qualitative and quantitative measurements.Keywords
This publication has 24 references indexed in Scilit:
- A low dose simulation tool for CT systems with energy integrating detectorsMedical Physics, 2013
- Variance analysis of x-ray CT sinograms in the presence of electronic noise backgroundMedical Physics, 2012
- An image-based approach to low-dose CT simulation2012
- Variance estimation of x-ray CT sinogram in radon domain2012
- A study on CT sinogram statistical distribution by information divergence theory2011
- Pediatric MDCTAcademic Radiology, 2009
- A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest RadiographyJournal of Digital Imaging, 2008
- Nonlinear sinogram smoothing for low-dose X-ray CTIEEE Transactions on Nuclear Science, 2004
- The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brainBritish Journal of Radiology, 2004
- Statistical image reconstruction for polyenergetic X-ray computed tomographyIEEE Transactions on Medical Imaging, 2002