A Tale of Four Danish Cities: Legionella pneumophila Diversity in Domestic Hot Water and Spatial Variations in Disease Incidence
Open Access
- 22 February 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2530
Abstract
Denmark has one of the highest Legionnaires’ disease notification rates within Europe, averaging 4.7 cases per 100,000 population annually (2017 to 2020). The relatively high incidence of disease is not uniform across the country, and approximately 70% of all domestically acquired cases in Denmark are caused by Legionella pneumophila (LP) strains that are considered less virulent. The aim of this study was to investigate if colonization rates, levels of colonization, and/or types of LP present in hot water systems were associated with geographic differences in Legionnaires’ disease incidence. Domestic water systems from four cities in Denmark were analyzed via culture and qPCR. Serogrouping and sequence typing was performed on randomly selected isolates. Single nucleotide polymorphism was used to identify clonal relationship among isolates from the four cities. The results revealed a high LP colonization rate from 68% to 87.5% among systems, composed primarily of non-serogroup 1. LP serogroup 1 reacting with the monoclonal antibody (MAb) 3/1 was not identified in any of the systems tested, while MAb 3/1 negative serogroup 1 strains were isolated from 10 systems (9.6%). We hypothesize that a combination of factors influences the incidence rate of LD in each city, including sequence type and serogroup distribution, colonization rate, concentration of Legionella in Pre-flush and Flush samples, and potentially building characteristics such as water temperature measured at the point of use.Keywords
Funding Information
- Danish Finance Act (2019 § 28.57.02.17.)
This publication has 49 references indexed in Scilit:
- Immunochromatic kits Xpect Legionella and BinaxNOW Legionella for detection of Legionella pneumophila urinary antigen have low sensitivities for the diagnosis of Legionnaires’ diseaseJournal of Medical Microbiology, 2012
- Legionella pneumophila serogroup 3 prevalence in drinking water survey in Israel (2003–2007)Water Supply, 2010
- Diagnostic and typing methods for investigating Legionella infectionNew South Wales Public Health Bulletin, 2009
- PCR-based ‘serotyping’ of Legionella pneumophilaJournal of Medical Microbiology, 2009
- Colonization ofLegionellaSpecies in Hotel Water Systems in TurkeyJournal of Travel Medicine, 2007
- Occurrence and distribution of sequence types among Legionella pneumophila strains isolated from patients in Germany: common features and differences to other regions of the worldEuropean Journal of Clinical Microbiology & Infectious Diseases, 2007
- Introduction of Monochloramine into a Municipal Water System: Impact on Colonization of Buildings by Legionella sppApplied and Environmental Microbiology, 2006
- Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systemsJournal of Applied Microbiology, 2004
- Clinical and Environmental Distributions of Legionella Strains in France Are DifferentJournal of Clinical Microbiology, 2004
- Pan-European Study on Culture-Proven Legionnaires' Disease: Distribution of Legionella pneumophila Serogroups and Monoclonal SubgroupsEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002