Modeling SSFP functional MRI contrast in the brain
Open Access
- 25 August 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (3) , 661-673
Abstract
Steady-state free precession (SSFP) has recently been proposed for function MRI because of the potential for reducing image distortion and signal dropout. Several different contrast mechanisms have been suggested to explain the reported observations, but there has been limited work comparing theory with experiment in the brain. Moreover, the detailed work that has considered oxygen-dependent signal in SSFP outside the brain has focused on R2 effects in the pass band, and largely neglected the signal contrast that occurs due to off-resonance effects. The article describes a model for SSFP functional contrast based on the convolution of the theoretical SSFP profile with the underlying frequency distribution. It is demonstrated that such a model must account for the effects of diffusion, which can alter the apparent R2 and linespread. Monte Carlo simulations are used to calibrate corrections for these terms. This new model has the computational efficiency of the convolution model while encapsulating information from more time-consuming Monte Carlo simulations. This corrected convolution model is shown to agree well with experimental data, and model predictions and limitations are discussed. Magn Reson Med 60:661–673, 2008.Keywords
This publication has 25 references indexed in Scilit:
- Deriving blood‐oxygen‐level‐dependent contrast in MRI with T‐weighted, T2‐prepared and phase‐cycled SSFP methods: Theory and experimentMagnetic Resonance in Medicine, 2008
- Signal and noise characteristics of SSFP FMRI: A comparison with GRE at multiple field strengthsNeuroImage, 2007
- Systematic investigation of balanced steady‐state free precession for functional MRI in the human visual cortex at 3 TeslaMagnetic Resonance in Medicine, 2006
- Effect of diffusion in inhomogeneous magnetic fields on balanced steady‐state free precessionNMR in Biomedicine, 2006
- Oxygen‐sensitive contrast in blood for steady‐state free precession imagingMagnetic Resonance in Medicine, 2005
- Functional brain imaging using a blood oxygenation sensitive steady stateMagnetic Resonance in Medicine, 2003
- Is TrueFISP a gradient‐echo or a spin‐echo sequence?Magnetic Resonance in Medicine, 2003
- Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary resultsNMR in Biomedicine, 2001
- Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fieldsMagnetic Resonance in Medicine, 1990
- Phase and intensity anomalies in fourier transform NMRJournal of Magnetic Resonance (1969), 1971