Abstract
In this study, an extraction and preconcentration technique using solid‐phase extraction (SPE) along with hollow fiber (HF) has been developed as an ultra‐preconcentration technique for some triazole pesticides in aqueous samples. Triazole pesticides were employed as model compounds to assess the method and were monitored by gas chromatography–flame ionization detection (GC‐FID). Initially, an aqueous solution of target analytes was passed through an RP‐8 SPE cartridge and then the adsorbed analytes were eluted with μL amounts of toluene. The collected elute was slowly introduced into an HF that had one end blocked. This allowed precipitation inside the lumen and pores of the HF. Finally, the obtained HF was mounted on a home‐made solid‐phase microextraction syringe and entered into the GC injection port for thermal desorption‐GC analysis. The effect of various experimental parameters including injection port temperature, desorption time, state of HF, washing solvent, elution solvent and its volume, sample volume, etc. were investigated for finding the optimum conditions. The calibration graphs were linear in the ranges of 2–1000 ng/mL (penconazole and hexaconazole), 5–1000 ng/mL (tebuconazole), 15–1000 ng/mL (triticonazole) and the detection limits (LODs) ranged from 0.6 to 4.5 ng/mL. The enhancement factors were in the range of 870–950. The relative standard deviations (RSD%) for five repeated experiments (C=250 ng/mL of each pesticide) varied from 4.5 to 8.7%. The relative recoveries obtained for analytes in grape juice samples, spiked with different levels of each pesticide, were in the range of 87–119%.Keywords
Funding Information
- Research Council of Tabriz University
This publication has 46 references indexed in Scilit:
- Isolation and preconcentration of Cd(II) from environmental samples using polypropylene porous membrane in a hollow fiber renewal liquid membrane extraction procedure and determination by FAASJournal of Hazardous Materials, 2010
- Miniaturized sample preparation needle: A versatile design for the rapid analysis of smoking-related compounds in hair and air samplesJournal of Pharmaceutical and Biomedical Analysis, 2007
- A new liquid-phase microextraction method based on solidification of floating organic dropAnalytica Chimica Acta, 2007
- An electropolymerized aniline-based fiber coating for solid phase microextraction of phenols from waterAnalytica Chimica Acta, 2005
- Hollow fiber membrane-protected solid-phase microextraction of triazine herbicides in bovine milk and sewage sludge samplesJournal of Chromatography A, 2004
- Single-drop microextraction for the analysis of organophosphorous insecticides in waterAnalytica Chimica Acta, 2004
- Homogeneous liquid–liquid extraction followed by X-ray fluorescence spectrometry of a microdroplet on filter-paper for the simultaneous determination of small amounts of metalsThe Analyst, 2000
- Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on-line solid-phase extraction-liquid chromatography–diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometryAnalytica Chimica Acta, 1999
- Comparative study of on-line solid phase extraction followed by UV and electrochemical detection in liquid chromatography for the determination of priority phenols in river water samplesAnalytica Chimica Acta, 1995
- Determination of phenol and monochlorophenols in water by reversed-phase liquid chromatographyAnalytica Chimica Acta, 1993