A tight squeeze: geometric effects on the performance of three-electrode electrochemical-aptamer based sensors in constrained, in vivo placements
Open Access
- 1 March 2023
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (7) , 1562-1569
Abstract
Electrochemical, aptamer-based (EAB) sensors are the first molecular monitoring technology that is (1) based on receptor binding and not the reactivity of the target, rendering it fairly general, and (2) able to support high-frequency, real-time measurements in situ in the living body. To date, EAB-derived in vivo measurements have largely been performed using three electrodes (working, reference, counter) bundled together within a catheter for insertion into the rat jugular. Exploring this architecture, here we show that the placement of these electrodes inside or outside of the lumen of the catheter significantly impacts sensor performance. Specifically, we find that retaining the counter electrode within the catheter increases the resistance between it and the working electrode, increasing the capacitive background. In contrast, extending the counter electrode outside the lumen of the catheter reduces this effect, significantly enhancing the signal-to-noise of intravenous molecular measurements. Exploring counter electrode geometries further, we find that they need not be larger than the working electrode. Putting these observations together, we have developed a new intravenous EAB architecture that achieves improved performance while remaining short enough to safely emplace in the rat jugular. These findings, though explored here with EAB sensors may prove important for the design of many electrochemical biosensors.Keywords
Funding Information
- Otis
- National Defense Science and Engineering Graduate
- Office of Naval Research Global (N00014-20-1-2164)
- National Institutes of Health (R01AI145206)
This publication has 20 references indexed in Scilit:
- A Practical Beginner’s Guide to Cyclic VoltammetryJournal of Chemical Education, 2017
- Real-time measurement of small molecules directly in awake, ambulatory animalsProceedings of the National Academy of Sciences, 2017
- Maximizing the Signal Gain of Electrochemical-DNA SensorsAnalytical Chemistry, 2016
- Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living AnimalsScience Translational Medicine, 2013
- An ultrasensitive universal detector based on neutralizer displacementNature Chemistry, 2012
- Fundamentals2007
- Femtomolar Electrochemical Detection of DNA Targets Using Metal Sulfide NanoparticlesJournal of the American Chemical Society, 2006
- Fundamentals of electrochemistry2005
- Electrochemical DNA Hybridization BiosensorsElectroanalysis, 2002
- Redox-Active Nucleic-Acid Replica for the Amplified Bioelectrocatalytic Detection of Viral DNAJournal of the American Chemical Society, 2002