Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis
- 14 September 2023
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (11) , 3430-3440
Abstract
Purpose To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases. Methods This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard. Results DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (p < 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (p < 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3–4.3] vs. 3.7 [3.0–4.0] vs. 3.7 [3.0–4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (p < 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (p = 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, p = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, p < 0.001). The specificities per lesion were not significantly different among the three algorithms (p = 0.15). Conclusion DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI. Graphical abstractKeywords
Funding Information
- ClariPI (06-2022-4530)
This publication has 24 references indexed in Scilit:
- Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic imagesClinical Imaging, 2017
- Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumorsAbdominal Radiology, 2016
- Presurgical Evaluation of Pancreatic Cancer: A Comprehensive Imaging Comparison of CT Versus MRIAmerican Journal of Roentgenology, 2016
- The Importance of Spectral SeparationInvestigative Radiology, 2015
- Dual-Energy CT: Oncologic ApplicationsAmerican Journal of Roentgenology, 2012
- Virtual Monochromatic Spectral Imaging for the Evaluation of Hypovascular Hepatic MetastasesInvestigative Radiology, 2012
- Dual Source Dual Energy MDCTInvestigative Radiology, 2010
- Bias in Research StudiesRadiology, 2006
- A software tool for increased efficiency in observer performance studies in radiologyRadiation Protection Dosimetry, 2005
- Liver metastases of colorectal cancer: US, CT or MR?Cancer Imaging, 2005