Stabilization of the Posteromedial Fragment in Bicondylar Tibial Plateau Fractures: A Mechanical Comparison of Locking and Nonlocking Single and Dual Plating Methods
Authors:
- Brad J. YooBYBrad J. Yoo
- Daphne M. BeingessnerDBDaphne M. Beingessner
- David P. BareiDBDavid P. Barei
- 1 July 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 69 (1) , 148-155
Abstract
The objective of this study is to compare locking and nonlocking single and dual plating constructs in maintaining posteromedial fragment reduction in a bicondylar tibial plateau fracture model. We hypothesized that posteromedial fragment fixation with medial and lateral nonlocked constructs would tolerate higher loads than with lateral locked constructs alone. Thirty composite tibiae were fractured (AO 41-C1.3). Six constructs were tested: (1) lateral 3.5-mm conventional nonlocking proximal tibial plate (CP); (2) CP + posteromedial 3.5-mm limited contact dynamic compression plate; (3) CP + posteromedial 1/3 tubular plate (CP + 1/3 tubular); (4) 3.5-mm Zimmer Proximal Tibial Locking plate; (5) 3.5-mm Synthes Locking Compression plate; and (6) Less Invasive Stabilization System tibial plate. Specimens were cyclically loaded to failure or a maximum of 4000 N. Failure occurred at the posteromedial fragment first. The CP + 1/3 tubular had the highest average load to failure (3040 N). The CP + 1/3 tubular demonstrated higher load at failure compared with the 3.5-mm Synthes Locking Compression plate (p = 0.0060) and the Less Invasive Stabilization System (p = 0.0360). The CP + 1/3 tubular did not demonstrate a difference in load at failure when compared with the CP (p = 0.4225), the CP + posteromedial 3.5-mm limited contact dynamic compression plate (p = 0.4799), or the 3.5-mm Zimmer Proximal Tibial Locking plate (p = 0.1595). The posteromedial fragment tolerated higher loads with the CP + 1/3 tubular plate construct. The superiority of this construct may be caused by unreliable penetration of this fragment by the lateral locking screws.Keywords
This publication has 23 references indexed in Scilit:
- Frequency and Fracture Morphology of the Posteromedial Fragment in Bicondylar Tibial Plateau Fracture PatternsJournal of Orthopaedic Trauma, 2008
- Functional Outcomes of Severe Bicondylar Tibial Plateau Fractures Treated with Dual Incisions and Medial and Lateral PlatesJournal of Bone and Joint Surgery, 2006
- Experimental model of tibial plateau fracture for biomechanical testingJournal of Biomechanics, 2006
- In Response:Journal of Orthopaedic Trauma, 2005
- Unstable Proximal Extraarticular Tibia FracturesJournal of Orthopaedic Trauma, 2004
- Split Depression Tibial Plateau Fractures: A Biomechanical StudyJournal of Orthopaedic Trauma, 2002
- Split Fractures of the Lateral Tibial Plateau: Evaluation of Three Fixation MethodsJournal of Orthopaedic Trauma, 1996
- Hybrid External Fixation of Comminuted Tibial Plateau FracturesClinical Orthopaedics and Related Research, 1996
- Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysisClinical Materials, 1994
- Tibial Plateau FracturesJournal of Orthopaedic Trauma, 1987