Effect of Telemonitoring of Cardiac Implantable Electronic Devices on Healthcare Utilization: A Meta-Analysis of Randomized Controlled Trials in Patients with Heart Failure
- 27 January 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 18 (2) , 195-204
Abstract
Aims Implantable device telemonitoring (DTM) is a diagnostic adjunct to traditional face-to-face hospital visits. Remote device follow-up and earlier diagnoses facilitated by DTM should reduce healthcare utilization. We explored whether DTM reduces healthcare utilization over standard of care (SoC), without compromising patient outcomes. Methods and results This systematic review and meta-analysis of 11 randomized controlled trials on DTM in patients with heart failure consisted of 5702 patients, with a median of 117 [interquartile range (IQR) 76–331] patients per study [age 65 years (IQR 63–67)] and follow-up range of 12–36 months. DTM was associated with a reduction in total number of visits [planned, unplanned, and emergency room (ER)] [relative risk (RR) 0.56; 95% confidence interval (CI) 0.43–0.73, P < 0.001]. Rates of cardiac hospitalizations (RR 0.96; 95% CI 0.82–1.12, P = 0.60) and the composite endpoints of ER, unplanned hospital visits, or hospitalizations (RR 0.99; 95% CI 0.68–1.43, P = 0.96) was similar between the DTM and the SoC groups. An increase in the total number of ER or unscheduled visits (RR 1.37; 95% CI 1.11–1.70, P = 0.004) was observed. This effect was consistent and statistically significant for all studies. Total and cardiac mortality were similar between the groups (DTM RR 0.90; 95% CI 0.69–1.16, P = 0.41; and DTM RR 0.93; 95% CI 0.51–1.69, P = 0.80). Monetary costs favoured DTM (10–55% reduction in five studies). Conclusions Compared with SoC, DTM is associated with a marked reduction in planned hospital visits. In addition, DTM was associated with lower monetary costs, despite a modest increase in unplanned hospital and ER visits. DTM did not compromise survival.Keywords
This publication has 21 references indexed in Scilit:
- Telemonitoring after discharge from hospital with heart failure: cost-effectiveness modelling of alternative service designsBMJ Open, 2013
- The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) Randomized Controlled Trial: Phase 1 Results on Dynamics of Early Intervention With Remote MonitoringJournal of Medical Internet Research, 2013
- Cost-Utility Analysis of the EVOLVO Study on Remote Monitoring for Heart Failure Patients With Implantable Defibrillators: Randomized Controlled TrialJournal of Medical Internet Research, 2013
- A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)European Heart Journal, 2011
- Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart FailureCirculation, 2011
- GRADE guidelines: 3. Rating the quality of evidenceJournal of Clinical Epidemiology, 2011
- The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) TrialJACC, 2011
- Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-UpCirculation, 2010
- Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-UpCirculation, 2010
- Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical TrialJournal of Cardiovascular Electrophysiology, 2010