Complications of anterior chamber lens implants and their effects on the endothelium
Authors:
- 1 November 1989
- journal article
- Published by Springer Nature in Eye
- Vol. 3 (6) , 690-695
Abstract
A five-year follow-up study of 186 eyes which were subject to intracapsular cataract extraction and rigid anterior chamber lens implantation is reported. Ninety-two per cent of cases achieved a visual acuity of 6/12 or better. Serial corneal endothelial cell counts were performed. In 37 pairs of eyes the median difference in operative endothelial cell loss between the operated and un-operated eyes was —7.3% (95% Confidence Interval from —8.7 to —6.1%). Iris tuck occurred in 22.0% and late 'iris ovalling' developed in a further 15.6% of eyes. The median operative endothelial cell loss for those eyes with iris tuck was —9.7% and this was significantly higher than that of eyes with no long-term complications (median loss = —7.3%). The median operative endothelial cell loss for those eyes which developed late ovalling was —8.0% and this was not significantly greater than that of the eyes with no long-term complications (p = 0.745). There was a progressive median endothelial cell loss for all operated eyes and this progressive cell loss was significantly greater for those eyes with iris tuck when compared with those with no complications (p = 0.045).Keywords
This publication has 21 references indexed in Scilit:
- Intraocular lenses. Histopathologic characteristics of a large series of autopsy eyesSurvey of Ophthalmology, 1985
- Shearing posterior chamber intraocular lenses: Five-year postoperative resultsAmerican Intra-Ocular Implant Society Journal, 1984
- Endothelial Cell Damage after Intracapsular Cataract Extraction and Primary Anterior Chamber Pseudophakos ImplantationOphthalmologica, 1983
- Anterior chamber lenses and severe segmental uveal ectropionAmerican Intra-Ocular Implant Society Journal, 1981
- Long-Term Changes in Corneal Endothelium Following Intraocular Lens ImplantationOphthalmology, 1981
- CORNEAL DAMAGE AFTER INTRAOCULAR SURGERYAustralian and New Zealand Journal of Ophthalmology, 1981
- A study of the anterior chamber before and after implantation of the Choyce Mark VIII lensAmerican Intra-Ocular Implant Society Journal, 1980
- CORNEAL THICKNESS AND ENDOTHELIAL DAMAGE AFTER INTRAOCULAR LENS IMPLANTATIONActa Ophthalmologica, 1980
- The Miami Cooperative Community Study on the Copeland Intraocular Lens (Pseudophakos)American Journal of Ophthalmology, 1976
- Long-term results of the Choyce anterior chamber lens implants Marks V, VII, and VIII.British Journal of Ophthalmology, 1975