Favorable Reoperation Rate at 2 Years Following Repair of Horizontal Cleavage Tears Using an All Suture‐Based Technique: A Prospective, Multicenter Trial
Authors:
Open Access
- 13 March 2021
- journal article
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 3 (3) , e773-e780
Abstract
Purpose: This prospective, multicenter trial evaluates the clinical success (as measured by reoperation rates and improvements in patient‐reported outcome measures) of using circumferential compression stitches with all‐suture techniques for horizontal cleavage tears (HCTs) of the meniscus. Methods: Investigators enrolled 30 patients (mean age, 38.2 years; standard deviation, 11.1 years) aged 18 to 60 years with HCTs in the symptomatic compartment at 8 centers in the United States who underwent HCT repair with all‐suture circumferential stitches using a self‐retrieving all‐inside suture passing device. Postoperative follow‐up visits were conducted at 6 months, 1 year, and 2 years. Study outcomes included freedom from reoperation of the index meniscus repair site; knee pain and function, as measured by International Knee Documentation Committee Knee evaluation (IKDC), Knee injury and Osteoarthritis Outcome Score, Lysholm Knee Scale, and Tegner Activity Scale; and serious complications observed during the study. Minimal clinically important difference at 1 year was assessed for IKDC and Lysholm. Results: Twenty‐three patients had 2‐year follow‐up data available. Freedom from reoperation was 96.0% at 6 months (26/27, 91.7% at 1 year [23/25], and 82.6% at 2 years [19/23]). Significant improvement was observed in over baseline at 2 years for IKDC (36.7‐82.5; P < .001), Knee injury and Osteoarthritis Outcome Score (52.2‐89.3; P < .001), Lysholm (50.2‐87.4; P < .001), and Tegner scores (3.3‐5.3; P = .007). Minimal clinically important difference was met or exceeded for IKDC and Lysholm scores at 1 year 69.2% and 65.4% of patients, respectively. Four patients (6.7%) experienced serious complications, of which 2 were assessed as being related to the procedure. Conclusions: Repair of HCTs using all‐suture circumferential stitches placed with a self‐retrieving all‐inside suture passing device leads to a favorable reoperation rate (17.4%), significant improvements in clinical outcomes, and an acceptable rate of serious complications (6.7%) at 2 years, supporting the viability of this treatment approach in this indication. Level of Evidence: Level IV, therapeutic case series.Keywords
Funding Information
- Arthrex
- Biomet
- DePuy Mitek
- Arthrex
- Biomet
- Arthrex
- Smith and Nephew
This publication has 29 references indexed in Scilit:
- The Circumferential Compression Stitch for Meniscus RepairArthroscopy Techniques, 2013
- Surgery versus Physical Therapy for a Meniscal Tear and OsteoarthritisNew England Journal of Medicine, 2013
- Surgical Options for Meniscal ReplacementJournal of the American Academy of Orthopaedic Surgeons, 2012
- Meniscectomy as a risk factor for knee osteoarthritis: a systematic reviewBritish Medical Bulletin, 2011
- MR Imaging of the Meniscus: Review, Current Trends, and Clinical ImplicationsRadiologic Clinics of North America, 2007
- Meniscal Repair Using the Inside-Out Suture TechniqueTechniques in Knee Surgery, 2007
- Benefit of Single-leaf Resection for Horizontal Meniscus TearClinical Orthopaedics and Related Research, 2007
- Is There an Association Between Articular Cartilage Changes and Degenerative Meniscus Tears?Arthroscopy, 2005
- Prospective Evaluation of 1485 Meniscal Tear Patterns in Patients with Stable KneesThe American Journal of Sports Medicine, 2004
- Meniscus preservation; rationale, repair techniques and resultsThe Knee, 2003