Experimental Determination of the Permeability in the Lacunar-Canalicular Porosity of Bone
- 2 September 2009
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 131 (10) , 101007
Abstract
Permeability of the mineralized bone tissue is a critical element in understanding fluid flow occurring in the lacunar-canalicular porosity (PLC) compartment of bone and its role in bone nutrition and mechanotransduction. However, the estimation of bone permeability at the tissue level is affected by the influence of the vascular porosity in macroscopic samples containing several osteons. In this communication, both analytical and experimental approaches are proposed to estimate the lacunar-canalicular permeability in a single osteon. Data from an experimental stress-relaxation test in a single osteon are used to derive the PLC permeability by curve fitting to theoretical results from a compressible transverse isotropic poroelastic model of a porous annular disk under a ramp loading history (2007, “Compressible and Incompressible Constituents in Anisotropic Poroelasticity: The Problem of Unconfined Compression of a Disk,” J. Mech. Phys. Solids, 55, pp. 161–193; 2008, “The Unconfined Compression of a Poroelastic Annular Cylindrical Disk,” Mech. Mater., 40(6), pp. 507–523). The PLC tissue intrinsic permeability in the radial direction of the osteon was found to be dependent on the strain rate used and within the range of . The reported values of PLC permeability are in reasonable agreement with previously reported values derived using finite element analysis (FEA) and nanoindentation approaches.
Keywords
This publication has 29 references indexed in Scilit:
- Poroelastic nanoindentation responses of hydrated boneJournal of Materials Research, 2008
- Inverse analysis of constitutive models: Biological soft tissuesJournal of Biomechanics, 2007
- Compressible and incompressible constituents in anisotropic poroelasticity: The problem of unconfined compression of a diskJournal of the Mechanics and Physics of Solids, 2007
- Quantitative 3D analysis of the canal network in cortical bone by micro‐computed tomographyThe Anatomical Record Part B: The New Anatomist, 2003
- Bone poroelasticityJournal of Biomechanics, 1999
- A case for bone canaliculi as the anatomical site of strain generated potentialsJournal of Biomechanics, 1995
- A comparative analysis of streaming potentials in vivo and in vitroJournal of Orthopaedic Research, 1992
- The effects of drying and re-wetting on some mechanical properties of cortical boneJournal of Biomechanics, 1988
- A continuous wave technique for the measurement of the elastic properties of cortical boneJournal of Biomechanics, 1984
- Isolation of single osteons and osteon lamellaeCells Tissues Organs, 1976