Polymer brush based fluorescent immunosensor for direct monitoring of interleukin-1β in rat blood
- 13 August 2019
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (19) , 5682-5690
Abstract
A sandwich immunosensor was successfully developed for monitoring of interleukin-1β (IL-1β) in rat whole blood. The substrate stainless steel (SS) was first coated with a polydopamine layer and subsequently grafted with poly(ethylene glycol) methacrylate brushes, onto which a sandwich immunosensor was modified for detection of IL-1β. The device has been successfully applied for monitoring of IL-1β with a limit of detection of 4.7 pg mL−1, and a linear detection range of 12.5–200 pg mL−1. Good specificity and selectivity for monitoring of IL-1β in rat macrophage secretion were achieved. Furthermore, this device was validated by detection of IL-1β in rat whole blood samples with greater concentrations observed in obese rats compared to control, and strong positive correlation between concentrations of IL-1β and blood glucose. These results suggest this device is feasible for direct detection of target analytes in biological samples.Keywords
Funding Information
- Australian Research Council (FT160100039, CE140100003)
- National Natural Science Foundation of China (21575045)
- National Health and Medical Research Council (1126929, 1091006)
- Rebecca L. Cooper Medical Research Foundation (RG160627)
- University of New South Wales
This publication has 41 references indexed in Scilit:
- N,N′-Carbonyldiimidazole-Mediated DBU-Catalyzed One-Pot Synthesis of Urea-Tethered Glycosyl Amino Acids and GlycoconjugatesSynlett, 2011
- Biocompatible Carbohydrate-Functionalized Stainless Steel Surfaces: A New Method For Passivating Biomedical ImplantsACS Applied Materials & Interfaces, 2011
- Interleukin-1 beta targeted therapy for type 2 diabetesExpert Opinion on Biological Therapy, 2009
- Evaluation of ion release, cytotoxicity, and platelet adhesion of electrochemical anodized 316 L stainless steel cardiovascular stentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- The future of drug-eluting stentsPharmacological Research, 2008
- The xMAP™ technique can be used for detection of the inflammatory cytokines IL-1β, IL-6 and TNF-α in bovine samplesVeterinary Immunology and Immunopathology, 2007
- Cellular Response to Magnetic Nanoparticles “PEGylated” via Surface-Initiated Atom Transfer Radical PolymerizationBiomacromolecules, 2006
- Interleukin-1 and neuronal injuryNature Reviews Immunology, 2005
- Creation and characterization of n-alkylthiol and n-alkylamine self-assembled monolayers on 316L stainless steelThin Solid Films, 2002
- Detection of interleukin-1 β in the tear fluid of patients with corneal disease with or without conjunctival involvementJapanese Journal of Ophthalmology, 1997