Microfluidic Mixers for Studying Protein Folding
Open Access
- 10 April 2012
- journal article
- video audio-media
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 62,p. e3976
Abstract
The process by which a protein folds into its native conformation is highly relevant to biology and human health yet still poorly understood. One reason for this is that folding takes place over a wide range of timescales, from nanoseconds to seconds or longer, depending on the protein1. Conventional stopped-flow mixers have allowed measurement of folding kinetics starting at about 1 ms. We have recently developed a microfluidic mixer that dilutes denaturant ~100-fold in ~8 μs2. Unlike a stopped-flow mixer, this mixer operates in the laminar flow regime in which turbulence does not occur. The absence of turbulence allows precise numeric simulation of all flows within the mixer with excellent agreement to experiment3-4. Laminar flow is achieved for Reynolds numbers Re ≤100. For aqueous solutions, this requires micron scale geometries. We use a hard substrate, such as silicon or fused silica, to make channels 5-10 μm wide and 10 μm deep (See Figure 1). The smallest dimensions, at the entrance to the mixing region, are on the order of 1 μm in size. The chip is sealed with a thin glass or fused silica coverslip for optical access. Typical total linear flow rates are ~1 m/s, yielding Re~10, but the protein consumption is only ~0.5 nL/s or 1.8 μL/hr. Protein concentration depends on the detection method: For tryptophan fluorescence the typical concentration is 100 μM (for 1 Trp/protein) and for FRET the typical concentration is ~100 nM. The folding process is initiated by rapid dilution of denaturant from 6 M to 0.06 M guanidine hydrochloride. The protein in high denaturant flows down a central channel and is met on either side at the mixing region by buffer without denaturant moving ~100 times faster (see Figure 2). This geometry causes rapid constriction of the protein flow into a narrow jet ~100 nm wide. Diffusion of the light denaturant molecules is very rapid, while diffusion of the heavy protein molecules is much slower, diffusing less than 1 μm in 1 ms. The difference in diffusion constant of the denaturant and the protein results in rapid dilution of the denaturant from the protein stream, reducing the effective concentration of the denaturant around the protein. The protein jet flows at a constant rate down the observation channel and fluorescence of the protein during folding can be observed using a scanning confocal microscope5.Keywords
This publication has 16 references indexed in Scilit:
- Evidence of Multiple Folding Pathways for the Villin Headpiece SubdomainThe Journal of Physical Chemistry B, 2011
- Ruggedness in the folding landscape of protein LHFSP Journal, 2008
- Protein Hydrophobic Collapse and Early Folding Steps Observed in a Microfluidic MixerBiophysical Journal, 2007
- Femtomole Mixer for Microsecond Kinetic Studies of Protein FoldingAnalytical Chemistry, 2004
- Collapse and search dynamics of apomyoglobin folding revealed by submillisecond observations of α-helical content and compactnessProceedings of the National Academy of Sciences, 2004
- Fast Kinetics and Mechanisms in Protein FoldingAnnual Review of Biophysics, 2000
- Compactness of the denatured state of a fast-folding protein measured by submillisecond small-angle x-ray scatteringProceedings of the National Academy of Sciences, 1999
- Evidence for barrier-limited protein folding kinetics on the microsecond time scaleNature Structural & Molecular Biology, 1998
- Submillisecond protein folding kinetics studied by ultrarapid mixingProceedings of the National Academy of Sciences, 1997
- Folding of cytochrome c initiated by submillisecond mixingNature Structural & Molecular Biology, 1997