Detection and Characterization of Microsecond Intermittent Faults in Wired Networks
- 18 July 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (9) , 2256-2258
Abstract
Intermittent faults (IFs), i.e., temporary malfunctions appearing at the random or periodic moments with normal behavior in between, are the measurable symptoms of the degradation of a system. Their frequency and severity increase over time, eventually leading to permanent faults. In order to optimally plan preventive maintenance, it is essential to catch IFs soon enough to repair them before they turn permanent. This paper introduces a new method, called continuous chaos time-domain reflectometry, which enables real-time monitoring of an electrical network and provides the detection and location information of microsecond IFs together with an estimation of their time of appearance and duration.Keywords
This publication has 7 references indexed in Scilit:
- Impact of Electrical Contact Resistance on the High-Speed Transmission and On-Line Diagnosis of Electrical Connector Intermittent FaultsIEEE Access, 2017
- Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current AnalysisIEEE Transactions on Instrumentation and Measurement, 2017
- Chaos time‐domain reflectometry for distributed diagnosis of complex topology wired networksElectronics Letters, 2016
- No Fault Found events in maintenance engineering Part 1: Current trends, implications and organizational practicesReliability Engineering & System Safety, 2014
- Cable Fault Localization Using Instantaneous Frequency Estimation in Gaussian-Enveloped Linear Chirp ReflectometryIEEE Transactions on Instrumentation and Measurement, 2012
- On line wire diagnosis using Multicarrier Time Domain Reflectometry for fault location2009
- Detection and location of intermittent faults by monitoring carrier signal channel behavior of electrical interconnection system2009