Magnetic field effects on the energy deposition spectra of MV photon radiation
Authors:
- T StanescuTST Stanescu
- B G FalloneBFB G Fallone
- 16 December 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (2) , 243-257
Abstract
Several groups worldwide have proposed various concepts for improving megavoltage (MV) radiotherapy that involve irradiating patients in the presence of a magnetic field-either for image guidance in the case of hybrid radiotherapy-MRI machines or for purposes of introducing tighter control over dose distributions. The presence of a magnetic field alters the trajectory of charged particles between interactions with the medium and thus has the potential to alter energy deposition patterns within a sub-cellular target volume. In this work, we use the MC radiation transport code PENELOPE with appropriate algorithms invoked to incorporate magnetic field deflections to investigate electron energy fluence in the presence of a uniform magnetic field and the energy deposition spectra within a 10 microm water sphere as a function of magnetic field strength. The simulations suggest only very minor changes to the electron fluence even for extremely strong magnetic fields. Further, calculations of the dose-averaged lineal energy indicate that a magnetic field strength of at least 70 T is required before beam quality will change by more than 2%.Keywords
This publication has 25 references indexed in Scilit:
- Experimental verification of magnetic field dose effects for the MRI-acceleratorPhysics in Medicine & Biology, 2007
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic fieldPhysics in Medicine & Biology, 2007
- Magnetic confinement of electron and photon radiotherapy dose: A Monte Carlo simulation with a nonuniform longitudinal magnetic fieldMedical Physics, 2005
- 2GHz 1H NMR in pulsed magnetsSolid State Nuclear Magnetic Resonance, 2005
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electronsPhysics in Medicine & Biology, 2005
- First 100 T non-destructive magnetIEEE Transactions on Applied Superconductivity, 2000
- A laboratory instrument for generating magnetic fields over 200 T with single turn coilsJournal of Physics E: Scientific Instruments, 1985
- Genetic effects of strong magnetic fields in drosophila melanogaster: II. Lack of interaction between homogeneous fields and fission neutron-plus-gamma radiationEnvironmental Mutagenesis, 1980
- Magnetic modification of the electron-dose distribution in tissue and lung phantomsMedical Physics, 1978
- An algorithm for LET-analysisPhysics in Medicine & Biology, 1972