Laparoscopic placement of peritoneal dialysis catheters: 7 years experience
Authors:
- 14 March 2003
- journal article
- research article
- Published by Wiley in Anz Journal of Surgery
- Vol. 73 (3) , 109-111
Abstract
Background: Since 1994 we have placed all peritoneal dialysis (Tenckhoff) catheters at our hospital laparoscopically using a technique that incorporates suture fixation into the pelvis. The purpose of this study was to determine the long‐term outcome of this approach.Method: Perioperative and follow‐up data for all patients undergoing placement of a peritoneal dialysis catheter at the Royal Adelaide Hospital were collected prospectively and managed on unit specific and hospital wide computerized databases. A total of 148 procedures were carried out in 123 patients from March 1994 to November 2001. Follow‐up ranged from 3 to 68 months (median, 42 months). All procedures were undertaken or supervised by one surgeon, and catheters were routinely sutured into the pelvis at laparoscopy.Results: There was no perioperative mortality in this series, and only one catheter could not be placed laparoscopically. This was in a patient with extensive intra‐abdominal adhesions. Mean operative time was 27 min (range, 10−100 min), and mean postoperative stay was 2.8 days (range, 1−12 days). Seven (5%) patients experienced peri/postoperative haemorrhage, and four of these underwent surgical re‐exploration. Twenty‐five (17%) catheters are still used for dialysis. Thirty‐four (23%) catheters were removed when the recipient received a subsequent renal transplant, and 42 (28%) patients died during follow‐up. Forty‐six (31%) patients required catheter revision or removal because of technical problems; 26 (18%) recurrent peritonitis or exit site infection; and 20 (14%) catheter blockage. Twenty‐eight reinsertion procedures were carried out in 25 patients. Ten (7%) patients developed port site hernias at late follow‐up, and required hernioplasty. Catheter migration leading to malfunction (poor drainage) occurred in eight (5%) patients only.Conclusions: Laparoscopic placement of peritoneal dialysis catheters is a safe and effective procedure. The majority of patients will dialyse successfully using this technique. Suturing the catheter tip into the pelvis is associated with a low rate of catheter migration.Keywords
This publication has 5 references indexed in Scilit:
- Survival and Complications of 225 Catheters Used in Continuous Ambulatory Peritoneal Dialysis: One-Center Experience in Northern GreecePeritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 1999
- A New Laparoscopic Method for Implantation of Peritoneal CathetersASAIO Journal, 1993
- Chronic Peritoneal Dialysis Access Jose A. Diaz‐Buxo, Series Editor: Mechanical Complications of Chronic Peritoneal Dialysis CathetersSeminars in Dialysis, 1991
- Chronic Peritoneal Dialysis Catheters: Effects of Catheter Design, Materials, and LocationSeminars in Dialysis, 1990
- PERFORATING INJURIES OF THE BOWEL COMPLICATING PERITONEAL CATHETER INSERTIONThe Lancet, 1968