Renal and Hepatic Function in Surgical Patients After Low-Flow Sevoflurane or Isoflurane Anesthesia
Authors:
- Kazuyuki IkedaKIKazuyuki Ikeda
- 1 January 1996
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 82 (1) , 173-176
Abstract
The safety of low-flow sevoflurane anesthesia, which produces higher concentrations of toxic compounds, has been questioned. One hundred surgical patients received sevoflurane or isoflurane anesthesia at a total flow rate of 1 L/min. End-tidal CO2 concentrations and inspired and end-tidal anesthetic concentrations were monitored during anesthesia. Pre- and postanesthetic clinical laboratory studies were performed in both groups, and no significant differences were found between groups. In the sevoflurane group, the concentrations of degradation products in the circuit were measured by gas chromatography and the temperature of the CO2 absorbent was also measured. Two degradation products were detected: CF2 = C(CF3-O-CH2F (Compound A) and CH3OCF2CH(CF3)OCH2F (Compound B). The highest measured mean concentration of Compound A was 24.6 +/- 7.2 (13.6-41.3) ppm, and that of Compound B (detected in 12 patients) was 1.5 ppm. In both groups, total bilirubin, direct bilirubin, aspartate aminotransferase, and alanine aminotransferase were increased postoperatively. There was no difference between groups. Low concentrations of Compound A were present in low-flow sevoflurane anesthesia, but no significant differences in clinical laboratory values were observed between low-flow sevoflurane and isoflurane anesthesia.Keywords
This publication has 16 references indexed in Scilit:
- Effect of total flow rate on the concentration of degradation products generated by reaction between sevoflurane and soda limeBritish Journal of Anaesthesia, 1995
- Plasma Inorganic Fluoride and Intracircuit Degradation Product Concentrations in Long-Duration, Low-Flow Sevoflurane AnesthesiaAnesthesia & Analgesia, 1994
- Toxicity of Compound A in RatsAnesthesiology, 1994
- Toxicity of Compound A in RatsAnesthesiology, 1994
- Closed-circuit Anesthesia with Sevoflurane in Humans Effects on Renal and Hepatic Function and Concentrations of Breakdown Products with Soda Lime in the CircuitAnesthesiology, 1994
- Reaction of Sevoflurane and Its Degradation Products with Soda LimeAnesthesiology, 1992
- Quantification of the Degradation Products of Sevoflurane in Two CO2 Absorbants during Low-flow Anesthesia in Surgical PatientsAnesthesiology, 1992
- The Safety of Sevoflurane in HumansAnesthesiology, 1992
- IsofluraneAnesthesia & Analgesia, 1981
- SevofluraneAnesthesia & Analgesia, 1975