Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments
- 20 July 2022
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 194 (9) , 1-15
Abstract
Over the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors’ response, especially in the case of PM10 concentrations (high overestimation).Keywords
This publication has 33 references indexed in Scilit:
- Respiratory effects of indoor particles in young children are size dependentScience of The Total Environment, 2011
- Non-exhaust emissions of PM and the efficiency of emission reduction by road sweeping and washing in the NetherlandsScience of The Total Environment, 2010
- Validation of continuous particle monitors for personal, indoor, and outdoor exposuresJournal of Exposure Science & Environmental Epidemiology, 2010
- Reduced NO and PM10 emissions on urban motorways in The Netherlands by 80 km/h speed managementScience of The Total Environment, 2010
- Analysis of air pollution caused by particle matter emission from the copper smelter complex Bor (Serbia)Chemical Industry and Chemical Engineering Quarterly, 2010
- Fine-Particulate Air Pollution and Life Expectancy in the United StatesNew England Journal of Medicine, 2009
- Spatial distribution of particulate matter (PM10 and PM2.5) in Seoul Metropolitan Subway stationsJournal of Hazardous Materials, 2008
- Effects of travel mode on exposures to particulate air pollutionEnvironment International, 2008
- Field performance of a nephelometer in rural kitchens: effects of high humidity excursions and correlations to gravimetric analysesJournal of Exposure Science & Environmental Epidemiology, 2006
- Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurementsAtmospheric Environment, 2004