On the Time Scale of Nocturnal Boundary Layer Cooling in Valleys and Basins and over Plains
Authors:
- Stephan F. J. De WekkerSWStephan F. J. De Wekker
- C. David WhitemanCWC. David Whiteman
- 1 June 2006
- journal article
- Published by American Meteorological Society in Journal of Applied Meteorology and Climatology
- Vol. 45 (6) , 813-820
Abstract
Sequences of vertical temperature soundings over flat plains and in a variety of valleys and basins of different sizes and shapes were used to determine cooling-time-scale characteristics in the nocturnal stable boundary layer under clear, undisturbed weather conditions. An exponential function predicts the cumulative boundary layer cooling well. The fitting parameter or time constant in the exponential function characterizes the cooling of the valley atmosphere and is equal to the time required for the cumulative cooling to attain 63.2% of its total nighttime value. The exponential fit finds time constants varying between 3 and 8 h. Calculated time constants are smallest in basins, are largest over plains, and are intermediate in valleys. Time constants were also calculated from air temperature measurements made at various heights on the sidewalls of a small basin. The variation with height of the time constant exhibited a characteristic parabolic shape in which the smallest time constants occur... Abstract Sequences of vertical temperature soundings over flat plains and in a variety of valleys and basins of different sizes and shapes were used to determine cooling-time-scale characteristics in the nocturnal stable boundary layer under clear, undisturbed weather conditions. An exponential function predicts the cumulative boundary layer cooling well. The fitting parameter or time constant in the exponential function characterizes the cooling of the valley atmosphere and is equal to the time required for the cumulative cooling to attain 63.2% of its total nighttime value. The exponential fit finds time constants varying between 3 and 8 h. Calculated time constants are smallest in basins, are largest over plains, and are intermediate in valleys. Time constants were also calculated from air temperature measurements made at various heights on the sidewalls of a small basin. The variation with height of the time constant exhibited a characteristic parabolic shape in which the smallest time constants occur...Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Vertical Soundings and Sidewall Air Temperature Measurements in a Small Alpine BasinJournal of Applied Meteorology and Climatology, 2004
- Minimum Temperatures, Diurnal Temperature Ranges, and Temperature Inversions in Limestone Sinkholes of Different Sizes and ShapesJournal of Applied Meteorology and Climatology, 2004
- What determines the nocturnal cooling timescale at 2 m?Geophysical Research Letters, 2004
- Heat Balance in the Nocturnal Boundary Layer during CASES-99Journal of Applied Meteorology and Climatology, 2003
- Mountain Meteorology2000
- Boundary Layer Evolution within a Canyonland Basin. Part I: Mass, Heat, and Moisture Budgets from ObservationsJournal of Applied Meteorology and Climatology, 1996
- The Nocturnal Surface Inversion and Influence of Clear-Air Radiative CoolingJournal of the Atmospheric Sciences, 1982
- NOTE ON THE THEORY OF NOCTURNAL RADIATIONAL COOLING OF THE EARTH'S SURFACEJournal of Meteorology, 1947
- Physical and Dynamical MeteorologyThe Geographical Journal, 1939