Watertight cataract incision closure using fibrin tissue adhesive
- 1 August 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (8) , 1461-1463
Abstract
To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.Keywords
This publication has 5 references indexed in Scilit:
- Cut and paste: a no suture, small incision approach to pterygium surgeryBritish Journal of Ophthalmology, 2004
- Dynamic morphology of clear corneal cataract incisionsOphthalmology, 2003
- Human fibrin tissue adhesive for sutureless lamellar keratoplasty and scleral patch adhesionOphthalmology, 2003
- Evaluation of tissue adhesives in closure of scleral tunnel incisionsJournal of Cataract & Refractive Surgery, 1995
- Organic tissue glue in the closure of cataract incisions in rabbit eyesJournal of Cataract & Refractive Surgery, 1991