Abstract
The acoustic power W radiated by a harmonic monopole of strength Q located in a rectangular reverberation chamber has been calculated by using an eigenfunction expansion of the Green's function. An expression for the sound intensity valid for small normal admittance β has been integrated over the chamber surfaces to determine the power output. The results are within approximately ±2 dB of the results obtained by Waterhouse and Cook when the source is near one or more reflecting surfaces. At low frequencies, the ratio of W to the free-space output W0 varies with source position within the chamber, and has been treated statistically. The space-averaged value of W/W0 is generally less than unity, but values in the range 0.1–10.0 occur for particular values of frequency and β. The normalized standard deviation of W/W0 lies in the range 0.3–0.4 for β=0.05, and increases as β decreases. The results are applicable to the choice of an optimum absorption characteristic for low-frequency pure-tone power-level measurements.