Neonatal blood culture inoculant volume: feasibility and challenges
- 6 April 2021
- journal article
- research article
- Published by Springer Nature in Pediatric Research
- Vol. 90 (5) , 1086-1092
Abstract
Background Clinicians often express concerns about poor sensitivity of blood cultures in neonates resulting from inadequate inoculant volumes. Our objective was to determine the inoculant volume sent for neonatal sepsis evaluations and identify areas of improvement. Methods Single-center prospective observational study of infants undergoing sepsis evaluation. Blood volume was determined by clinician documentation over 21 months, and additionally by weighing culture bottles during 12 months. Adequate volume was defined as ≥1 mL total inoculant per evaluation. For first-time evaluations, local guidelines recommend sending an aerobic–anaerobic pair with 1 mL inoculant in each. Results There were 987 evaluations in 788 infants. Clinicians reported ≥1 mL total inoculant in 96.9% evaluations. Among 544 evaluations where bottles were weighed, 93.4% had ≥1 mL total inoculant. Very low birth weight infants undergoing evaluations >7 days after birth had the highest proportion of inadequate inoculants (14.4%). Only 3/544 evaluations and 26/1011 bottles had total inoculant 90% of evaluations have ≥1 mL inoculant. Monitoring adequacy of blood culture technique can identify areas of improvement and may allay concerns about blood culture reliability. Current recommendations for adequate inoculant volume for blood cultures are met in a majority of neonates. Areas of improvement include preterm late-onset sepsis evaluations and distribution techniques during inoculation.Keywords
This publication has 37 references indexed in Scilit:
- Education of Phlebotomy Teams Improves Blood Volume in Blood Culture BottlesJournal of Clinical Microbiology, 2013
- Using umbilical cord blood for the initial blood tests of VLBW neonates results in higher hemoglobin and fewer RBC transfusionsJournal of Perinatology, 2012
- The Burden of Invasive Early-onset Neonatal Sepsis in the United States, 2005–2008The Pediatric Infectious Disease Journal, 2011
- Is the Volume of Blood Cultured Still a Significant Factor in the Diagnosis of Bloodstream Infections?Journal of Clinical Microbiology, 2007
- How Reliable Is a Negative Blood Culture Result? Volume of Blood Submitted for Culture in Routine Practice in a Children's HospitalPediatrics, 2007
- Optimal Testing Parameters for Blood CulturesClinical Infectious Diseases, 2004
- Comparison of Recovery of Blood Culture Isolates from Two BacT/ALERT FAN Aerobic Blood Culture Bottles with Recovery from One FAN Aerobic Bottle and One FAN Anaerobic BottleJournal of Clinical Microbiology, 2003
- Volume of blood required to detect common neonatal pathogensThe Journal of Pediatrics, 1996
- Value of routine anaerobic blood cultures for pediatric patientsThe Journal of Pediatrics, 1995
- The effect of dilution during culture on detection of low concentrations of bacteria in bloodThe Pediatric Infectious Disease Journal, 1984