An Evaluation of Portable Wet Bulb Globe Temperature Monitor Accuracy
- 1 December 2017
- journal article
- research article
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 52 (12) , 1161-1167
Abstract
Context: : Wet bulb globe temperature (WBGT) is the gold standard for assessing environmental heat stress during physical activity. Many manufacturers of commercially available instruments fail to report WBGT accuracy.Objective: : To determine the accuracy of several commercially available WBGT monitors compared with a standardized reference device.Design: : Observational study.Setting: : Field test.Patients or Other Participants: : Six commercially available WBGT devices.Main Outcome Measure(s): : Data were recorded for 3 sessions (1 in the morning and 2 in the afternoon) at 2-minute intervals for at least 2 hours. Mean absolute error (MAE), root mean square error (RMSE), mean bias error (MBE), and the Pearson correlation coefficient (r) were calculated to determine instrument performance compared with the reference unit.Results: : The QUESTemp° 34 (MAE = 0.24°C, RMSE = 0.44°C, MBE = –0.64%) and Extech HT30 Heat Stress Wet Bulb Globe Temperature Meter (Extech; MAE = 0.61°C, RMSE = 0.79°C, MBE = 0.44%) demonstrated the least error in relation to the reference standard, whereas the General WBGT8778 Heat Index Checker (General; MAE = 1.18°C, RMSE = 1.34°C, MBE = 4.25%) performed the poorest. The QUESTemp° 34 and Kestrel 4400 Heat Stress Tracker units provided conservative measurements that slightly overestimated the WBGT provided by the reference unit. Finally, instruments using the psychrometric wet bulb temperature (General, REED Heat Index WBGT Meter, and WBGT-103 Heat Stroke Checker) tended to underestimate the WBGT, and the resulting values more frequently fell into WBGT-based activity categories with fewer restrictions as defined by the American College of Sports Medicine.Conclusions: : The QUESTemp° 34, followed by the Extech, had the smallest error compared with the reference unit. Moreover, the QUESTemp° 34, Extech, and Kestrel units appeared to offer conservative yet accurate assessments of the WBGT, potentially minimizing the risk of allowing physical activity to continue in stressful heat environments. Instruments using the psychrometric wet bulb temperature tended to underestimate WBGT under low wind-speed conditions. Accurate WBGT interpretations are important to enable clinicians to guide activities in hot and humid weather conditions.Keywords
This publication has 12 references indexed in Scilit:
- Exertional Heat Illness in American Football Players: When Is the Risk Greatest?Journal of Athletic Training, 2016
- National Athletic Trainers' Association Position Statement: Exertional Heat IllnessesJournal of Athletic Training, 2015
- Empirical Approach to Outdoor WBGT from Meteorological Data and Performance of Two Different Instrument DesignsIndustrial Health, 2013
- Epidemiology of Exertional Heat Illness Among U.S. High School AthletesAmerican Journal of Preventive Medicine, 2013
- Calculating Workplace WBGT from Meteorological Data: A Tool for Climate Change AssessmentIndustrial Health, 2012
- Climatic Heat Stress and Exercising Children and AdolescentsPediatrics, 2011
- A retrospective analysis of American football hyperthermia deaths in the United StatesInternational Journal of Biometeorology, 2010
- Exertional Heat Illness during Training and CompetitionMedicine & Science in Sports & Exercise, 2007
- Three instruments for assessment of WBGT and a comparison with WGT (Botsball)AIHA Journal, 1980
- Globe Thermometer EvaluationAIHA Journal, 1974