PD pattern analysis during induced test of large power transformers

Authors:
  • EGE. Gulski
    E. Gulski
  • HBH.P. Burger
    H.P. Burger
  • GVG.H. Vaillancourt
    G.H. Vaillancourt
  • RBR. Brooks
    R. Brooks

Abstract
The partial discharge (I'D) aeasureinei~ts on powcr transfortncrs arc studied with IZ view to- ward discrimination and claasificatioii of diffcrcirt discliargc sonrccs. For this purposc digital analysis is applied to power transformers and renctois going through acceptance testing. Fur- thermore, based OH these measurements, PU databases havc been developed to support thc discharge evaluation during iiiduced voltage tests of transformers. Using this technique, a clear distinction is possible betwecn iransforiiwrs showing diffcrcnt discharge behavior.