Technical and Clinical Outcome of Low-Milliampere CT Fluoroscopy-Guided Percutaneous Drainage Placement in Abdominal Fluid Collections after Liver Transplantation: A 16-Year Retrospective Analysis of 50 Consecutive Patients
Authors:
- Robert StahlRSRobert Stahl
- Max SeidenstickerMSMax Seidensticker
- Helmut ArbogastHAHelmut Arbogast
- David KuppingerDKDavid Kuppinger
- Veronika GreifVGVeronika Greif
- Alexander CrispinACAlexander Crispin
- Melvin D’anastasiMDMelvin D’anastasi
- Vera PedersenVPVera Pedersen
- Robert ForbrigRFRobert Forbrig
- Thomas LiebigTLThomas Liebig
- Tim RutetzkiTRTim Rutetzki
- Christoph G. TrummChristoph G. Trumm
Open Access
- 6 February 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (4) , 353
Abstract
Purpose: Evaluation of the effectiveness of CT-guided drainage (CTD) placement in managing symptomatic postoperative fluid collections in liver transplant patients. The assessment included technical success, clinical outcomes, and the occurrence of complications during the peri-interventional period. Methods: Analysis spanned the years 2005 to 2020 and involved 91 drain placement sessions in 50 patients using percutaneous transabdominal or transhepatic access. Criteria for technical success (TS) included (a) achieving adequate drainage of the fluid collection and (b) the absence of peri-interventional complications necessitating minor or prolonged hospitalization. Clinical success (CS) was characterized by (a) a reduction or normalization of inflammatory blood parameters within 30 days after CTD placement and (b) the absence of a need for surgical revision within 60 days after the intervention. Inflammatory markers in terms of C-reactive protein (CRP), leukocyte count and interleukin-6, were evaluated. The dose length product (DLP) for various intervention steps was calculated. Results: The TS rate was 93.4%. CS rates were 64.3% for CRP, 77.8% for leukocytes, and 54.5% for interleukin-6. Median time until successful decrease was 5.0 days for CRP and 3.0 days for leukocytes and interleukin-6. Surgical revision was not necessary in 94.0% of the cases. During the second half of the observation period, there was a trend (p = 0.328) towards a lower DLP for the entire intervention procedure (median: years 2013 to 2020: 623.0 mGy·cm vs. years 2005 to 2012: 811.5 mGy·cm). DLP for the CT fluoroscopy component was significantly (p = 0.001) lower in the later period (median: years 2013 to 2020: 31.0 mGy·cm vs. years 2005 to 2012: 80.5 mGy·cm). Conclusions: The TS rate of CT-guided drainage (CTD) placement was notably high. The CS rate ranged from fair to good. The reduction in radiation exposure over time can be attributed to advancements in CT technology and the growing expertise of interventional radiologists.Keywords
This publication has 40 references indexed in Scilit:
- CT-guided percutaneous drainage of abdominopelvic collections: a pictorial essayLa radiologia medica, 2021
- Complications of liver transplantAbdominal Radiology, 2019
- Bending percutaneous drainage catheters to facilitate CT-guided insertion using curved trocar techniqueAbdominal Radiology, 2017
- Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstructionEuropean Radiology, 2017
- CT-SteuerungDer Radiologe, 2013
- Image-guided percutaneous treatment of abdominal-pelvic abscesses: a 5-year experienceLa radiologia medica, 2008
- Microbiology and Management of Abdominal InfectionsDigestive Diseases and Sciences, 2008
- Percutaneous Drainage of 300 Intraperitoneal Abscesses with Long-Term Follow-UpCardioVascular and Interventional Radiology, 2005
- CT-guided percutaneous drainage of intra-abdominal abscesses: APACHE III score stratification of 1-year resultsEuropean Radiology, 2002
- Percutaneous Abscess Drainage: UpdateWorld Journal of Surgery, 2001