Abstract
A sensitive detection method combined with an effective on-line concentration may improve the analytical performance of a paper-based analytical device (PAD), and its merits of low cost and portability in POCT are fully demonstrated. Here, a sensitive PAD system with chemiluminescence (CL) detection and electrokinetic preconcentration was introduced, and the performance was demonstrated by the detection of hemin. A commercially available low cost and miniaturized optical detection module was used for the CL detection. Firstly, hemin was stacked on a simple paper fluidic channel based on field amplified stacking (FAS), and then a CL reagent (luminol–H2O2) was loaded on the stacked band to initiate the CL reaction. The photons were directly detected using the detection module. With optimization of the background electrolyte (BGE), voltage and CL reagent, a limit of detection (LOD) of 0.58 nM for hemin was obtained with a linear range of 1–1000 nM (R2 = 0.995). With FAS, the signal intensity was about 13-fold enhanced. This PAD also exhibited satisfactory selectivity over possible interfering components at a 104 times higher concentration. The applicability of the PAD was demonstrated by the detection of hemin from iron supplements and human serum samples. With total manual operation, recovery rates of 84.8–115.6% were obtained with an RSD of less than 14.3%. With the introduction of the optical detection model, and together with FAS, both the LOD and dynamic range of this PAD were effectively improved.Keywords
Funding Information
- National Natural Science Foundation of China (21575019)
- Department of Education of Liaoning Province (LZ2015036)
This publication has 39 references indexed in Scilit:
- A simple and sensitive fluorescent assay for hemin detection based on artemisinin-thiamineSensors and Actuators B: Chemical, 2018
- Flexible Electronics Based on Micro/Nanostructured PaperAdvanced Materials, 2018
- Performance of electrokinetic stacking enhanced paper-based analytical device with smartphone for fast detection of fluorescent whitening agentAnalytica Chimica Acta, 2017
- Separation and preconcentration of hemin from serum samples followed by voltammetric determinationJournal of Molecular Liquids, 2017
- A simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detectionBiosensors and Bioelectronics, 2015
- Lab-on-paper-based devices using chemiluminescence and electrogenerated chemiluminescence detectionAnalytical and Bioanalytical Chemistry, 2014
- Advances in paper-based point-of-care diagnosticsBiosensors and Bioelectronics, 2014
- Paper-based chemiluminescence ELISA: Lab-on-paper based on chitosan modified paper device and wax-screen-printingBiosensors and Bioelectronics, 2012
- A spectrophotometric method for estimating hemin in biological systemsAnalytical Biochemistry, 2005
- Flow Injection Chemiluminescence Determination of Hemin Using the Rhodamine B?H2O2?NaOH SystemMicrochimica Acta, 2005