Abstract
The world’s first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (rf) cavities treated by medium-temperature furnace baking (mid-T bake) was developed at the Institute of High Energy Physics, Chinese Academy of Sciences. The 9-cell cavities in the cryomodule achieved an unprecedented high average intrinsic quality factor (Q0) of 3.8×1010 at 16  MV/m and 3.6×1010 at 21  MV/m in the horizontal test. The cryomodule can operate stably up to a total continuous wave rf voltage greater than 193 MV, with an average cavity usable accelerating gradient of more than 23  MV/m. The results significantly exceed the specifications of Circular Electron Positron Collider and Dalian advanced light source and the other high repetition rate free electron laser facilities [Linac Coherent Light Source II (LCLS-II), LCLS-II-high energy, Shanghai High Repetition Rate X-ray FEL and Extreme Light Facility, Shenzhen Superconducting Soft X-Ray Free Electron Laser, etc.]. There is evidence that the mid-T bake cavity may not require fast cooldown or long processing time in the cryomodule. This paper reviews the cryomodule performance and discusses some important issues in cryomodule assembly and testing.