Inclined load capacity of suction caissons
Authors:
- 15 September 2003
- journal article
- research article
- Published by Wiley in International Journal for Numerical and Analytical Methods in Geomechanics
- Vol. 27 (14) , 1235-1254
Abstract
A simplified method of analysis for estimating lateral load capacity of suction caisson anchors based on an upper bound plasticity formulation is presented. The simplification restricts the analysis to caissons in uniform and linearly varying undrained strength profiles; nevertheless, its computational efficiency permits quick evaluation of a number of parameters affecting load capacity. The validity and limitations of the simplified formulation are demonstrated through comparisons to more rigorous finite element solutions. A series of sensitivity studies demonstrate the effects of various soil conditions and loading parameters. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 5 references indexed in Scilit:
- Combined loading of skirted foundationsGéotechnique, 1998
- P ‐Ultimate for Undrained Analysis of Laterally Loaded PilesJournal of Geotechnical Engineering, 1993
- The limiting pressure on a circular pile loaded laterally in cohesive soilGéotechnique, 1984
- Field Testing and Analysis of Laterally Loaded Piles om Stiff Clay1975
- Correlation for Design of Laterally Loaded Piles in Soft Clay1970