Computerized Adaptive Test for Patients With Lumbar Spine Impairments Produced Valid and Responsive Measures of Function
Authors:
- Dennis L. HartDHDennis L. Hart
- Mark W. WernekeMWMark W. Werneke
- Ying-Chih WangYWYing-Chih Wang
- Paul W. StratfordPSPaul W. Stratford
- Jerome E. MioduskiJMJerome E. Mioduski
- 1 November 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 35 (24) , 2157-2164
Abstract
Outcomes instrument validation study. We evaluated administrative efficiency and psychometric adequacy of a computerized adaptive test (CAT) for patients with lumbar spine impairments seeking rehabilitation in outpatient therapy clinics. CATs promise efficient outcomes data collection in clinical applications with little loss of measurement precision compared to paper and pencil surveys. The lumbar CAT has been developed and simulated and is currently used routinely in therapy clinics. The CAT has not been assessed for administrative efficiency, and the outcomes measures estimated using the CAT have not been assessed using prospective data collection for validity, sensitivity to change, or responsiveness. Data from 17,439 patients with lumbar spine impairments receiving outpatient rehabilitation in 377 clinics in 30 states (United States) were analyzed. We evaluated efficiency of routine CAT administration and assessed construct validity, sensitivity to change, and responsiveness of CAT measures of lumbar functional status (FS). On average, patients took less than 2 minutes (standard deviation <1 minute) to answer 7 CAT items (standard deviation, 3), which produced precise estimates of FS that adequately covered the content range with negligible floor and ceiling effects. Patients who were older had more chronic symptoms, had more surgeries, had more comorbidities, and did not exercise before receiving rehabilitation reported worse discharge FS. A total of 66% of patients obtained statistically significant change (95% confidence interval minimal detectable change) at discharge. Change of 5 FS units (scale, 0-100) represented minimal clinically important improvement, which 70% of patients obtained. Minimal detectable change and minimal clinically important improvement were associated with intake FS. We concluded the lumbar CAT administration was efficient, and CAT FS measures were precise, valid, sensitive, and responsive, supporting lumbar CAT use in clinical and research applications.Keywords
This publication has 50 references indexed in Scilit:
- A Computerized Adaptive Test for Patients With Hip Impairments Produced Valid and Responsive Measures of FunctionArchives of Physical Medicine and Rehabilitation, 2008
- Computerized adaptive test for patients with knee impairments produced valid and responsive measures of functionJournal of Clinical Epidemiology, 2008
- Computerized adaptive test for patients with foot or ankle impairments produced valid and responsive measures of functionQuality of Life Research, 2008
- Implementing an Integrated Electronic Outcomes and Electronic Health Record Process to Create a Foundation for Clinical Practice ImprovementPhysical Therapy, 2008
- Assessing Mobility in Children Using a Computer Adaptive Testing Version of the Pediatric Evaluation of Disability InventoryArchives of Physical Medicine and Rehabilitation, 2005
- Item response theory and computerized adaptive testing: Implications for outcomes measurement in rehabilitation.Rehabilitation Psychology, 2005
- Score comparability of short forms and computerized adaptive testing: simulation study with the activity measure for post-acute careArchives of Physical Medicine and Rehabilitation, 2004
- Applications of computerized adaptive testing (CAT) to the assessment of headache impactQuality of Life Research, 2003
- Item Response Theory and Health Outcomes Measurement in the 21st CenturyMedical Care, 2000
- Response to Hays et al and McHorney and Cohen: Practical Implications of Item Response Theory and Computerized Adaptive TestingMedical Care, 2000