Maintaining high precision of isotope ratio analysis over extended periods of time
- 1 June 2009
- journal article
- research article
- Published by Taylor & Francis in Isotopes in Environmental and Health Studies
- Vol. 45 (2) , 135-149
Abstract
Stable isotope ratios are reliable and long lasting process tracers. In order to compare data from different locations or different sampling times at a high level of precision, a measurement strategy must include reliable traceability to an international stable isotope scale via a reference material (RM). Since these international RMs are available in low quantities only, we have developed our own analysis schemes involving laboratory working RM. In addition, quality assurance RMs are used to control the long-term performance of the δ-value assignments. The analysis schemes allow the construction of quality assurance performance charts over years of operation. In this contribution, the performance of three typical techniques established in IsoLab at the MPI-BGC in Jena is discussed. The techniques are (1) isotope ratio mass spectrometry with an elemental analyser for δ15N and δ13C analysis of bulk (organic) material, (2) high precision δ13C and δ18O analysis of CO2 in clean-air samples, and (3) stable isotope analysis of water samples using a high-temperature reaction with carbon. In addition, reference strategies on a laser ablation system for high spatial resolution δ13C analysis in tree rings is exemplified briefly.Keywords
This publication has 7 references indexed in Scilit:
- Laser ablation-combustion-GC-IRMS--a new method for online analysis of intra-annual variation of 13C in tree ringsTree Physiology, 2004
- Continuous flow 2 H/ 1 H and 18 O/ 16 O analysis of water samples with dual inlet precisionRapid Communications in Mass Spectrometry, 2004
- Two new organic reference materials for δ 13 C and δ 15 N measurements and a new value for the δ 13 C of NBS 22 oilRapid Communications in Mass Spectrometry, 2003
- Improved precision of coupled δ 13 C and δ 15 N measurements from single samples using an elemental analyzer/isotope ratio mass spectrometer combination with a post‐column six‐port valve and selective CO 2 trapping; improved halide robustness of the combustion reactor using CeO 2Rapid Communications in Mass Spectrometry, 2003
- Extraction of CO 2 from air samples for isotopic analysis and limits to ultra high precision δ 18 O determination in CO 2 gasRapid Communications in Mass Spectrometry, 2001
- A laser extraction/combustion technique for in situ δ13C analysis of organic and inorganic materialsRapid Communications in Mass Spectrometry, 1999
- ConFlo III - an interface for high precision δ13C and δ15N analysis with an extended dynamic rangeRapid Communications in Mass Spectrometry, 1999