Do Serologic and Synovial Tests Help Diagnose Infection in Revision Hip Arthroplasty With Metal-on-metal Bearings or Corrosion?
- 1 February 2015
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 473 (2) , 498-505
Abstract
The diagnosis of periprosthetic joint infection (PJI) in patients with failed metal-on-metal (MoM) bearings and corrosion reactions in hip arthroplasties can be particularly difficult, because the clinical presentation of adverse local tissue reactions may mimic that of PJI, because it can also occur concurrently with PJI, and because common laboratory tests used to diagnose PJI may be elevated in patients with MoM THAs. We sought to determine the test properties of the serum erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), synovial fluid white blood cell (WBC) count, and synovial fluid differential (percent polymorphonuclear cells [PMNs]) in diagnosing PJI in either MoM hips undergoing revision for a variety of indications or in non-MoM hips undergoing revision for either corrosion reaction or full-thickness wear. Additionally, we sought to describe how MoM bearings, metal debris, and corrosion reactions can confound the analysis of the synovial fluid WBC count and affect its diagnostic use for PJI. We reviewed 150 revision hips meeting specified inclusion criteria (92 MoM total hips, 19 MoM hip resurfacings, 30 non-MoM bearings with corrosion, and nine full-thickness bearing surface wear with metallosis). In our review, we diagnosed 19 patients as infected using Musculoskeletal Infection Society (MSIS) criteria. Mean laboratory values were compared between infected and not infected patients and receiver operator characteristic curves were generated with an area under the curve (AUC) to determine test performance and optimal cutoffs. After excluding the inaccurate synovial fluid samples, the synovial fluid WBC count (performed accurately in 102 patients) was the best test for the diagnosis of PJI (AUC = 98%, optimal cutoff 4350 WBC/μL) followed by the differential (performed accurately in 102 patients; AUC = 90%, optimal cutoff 85% PMN). The ESR (performed in 131 patients) and CRP (performed in 129 patients) both had good sensitivity (83% and 94%, respectively). Patients meeting MSIS criteria for PJI had higher mean serum ESR, CRP, synovial fluid WBC count, and differential than those not meeting MSIS criteria (p < 0.05 for all). An observer blinded to the MSIS diagnosis of the patient assessed the synovial fluid samples for inaccuracy secondary to metal or cellular debris. Synovial fluid sample “inaccuracy” was defined as the laboratory technician noting the presence of metal or amorpous material, fragmented cells, or clots, or the sample having some defect preventing an automated cell count from being performed. Of the 141 patients who had a synovial fluid sample initially available for review, 47 (33%) had a synovial fluid sample deemed to be inaccurate. A synovial fluid WBC count was still reported; however, 35 of these 47 hips (75%) and 11 of these 35 (31%) were falsely positive for infection. The diagnosis of PJI is extremely difficult in patients with MoM bearings or corrosion and the synovial fluid WBC count can frequently be falsely positive and should be relied on only if a manual count is done and if a differential can be performed. A more aggressive approach to preoperative evaluation for PJI is recommended in these patients to allow for careful evaluation of the synovial fluid specimen, the integration of synovial fluid culture results, and repeat aspiration if necessary. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 37 references indexed in Scilit:
- New Definition for Periprosthetic Joint Infection: From the Workgroup of the Musculoskeletal Infection SocietyClinical Orthopaedics and Related Research, 2011
- Adverse reaction to metal debris following hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2011
- The Mark Coventry Award: Diagnosis of Early Postoperative TKA Infection Using Synovial Fluid AnalysisClinical Orthopaedics and Related Research, 2011
- Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2010
- Diagnosis of Infected Total Knee: Findings of a Multicenter DatabaseClinical Orthopaedics and Related Research, 2008
- Preoperative Testing for Sepsis Before Revision Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- Sonication of Removed Hip and Knee Prostheses for Diagnosis of InfectionThe New England journal of medicine, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Inflammatory response in 85 patients with loosened hip prostheses: A prospective study comparing inflammatory markers in patients with aseptic and septic prosthetic looseningActa Orthopaedica, 2007
- Infection in Total Knee ReplacementClinical Orthopaedics and Related Research, 2001