The Position Readout and Survey system of the LHC collimators has to monitor in real time (RT), at a frequency close to 100 Hz, the position of the 555 synchronized axes with an accuracy of 20 mum. Radiation hard Linear Variable Differential Transformers (LVDT) are used as absolute position sensors for their ruggedness, intrinsic accuracy and infinite resolution. Because of the radioactive environment the conditioning electronics is located in safe zones up to 800 m away from the sensors. Under these conditions, standard conditioning techniques cannot guarantee the accuracy requested by this application because of cable impedance, noise immunity, crosstalk between signals of different sensors passing within the same multiwire cable and temperature stability. A fully digital approach based on a sine-fit algorithm has been followed and will be described showing the excellent results measured up to now. Particular attention is devoted to the RT implementation of the algorithm on the PXI platform from National Instruments.Keywords
This publication has 4 references indexed in Scilit:
- LHC Collimators Low Level Control SystemIEEE Transactions on Nuclear Science, 2008
- Test and comparison of LVDT signal conditioner performance2002
- Application of an FFT-based algorithm to signal processing of LVDT position sensorsIEEE Transactions on Instrumentation and Measurement, 1998
- A generalized inverse for matricesMathematical Proceedings of the Cambridge Philosophical Society, 1955