Aims: Sacral neuromodulation (SNM) is a guideline‐recommended treatment for voiding dysfunction including urgency, urge incontinence, and nonobstructive retention as well as fecal incontinence. The Axonics® System is a miniaturized, rechargeable SNM system designed to provide therapy for at least 15 years, which is expected to significantly reduce revision surgeries as it will not require replacement as frequently as the non‐rechargeable SNM system. The ARTISAN‐SNM study is a pivotal study designed to treat patients with urinary urgency incontinence (UUI). Clinical results at 1‐year are presented.Methods: A total of 129 eligible UUI patients were treated. All participants were implanted with a quadripolar tined lead and neurostimulator in a single procedure. Efficacy data were collected using a 3‐day bladder diary, a validated quality of life questionnaire (ICIQ‐OABqol), and a participant satisfaction questionnaire. Therapy responders were defined as participants with ≥50% reduction in UUI episodes compared to baseline. Data were analyzed on all 129 participants.Results: At 1 year, 89% of the participants were therapy responders. The average UUI episodes per day reduced from 5.6 ± 0.3 at baseline to 1.4 ± 0.2. Participants experienced an overall clinically meaningful improvement of 34 points on the ICIQ‐OABqol questionnaire. All study participants (100%) were able to recharge their device at 1 year, and 96% of participants reported that the frequency and duration of recharging was acceptable. There were no serious device‐related adverse events.Conclusions: The Axonics System is safe and effective at 1 year, with 89% of participants experiencing clinically and statistically significant improvements in UUI symptoms.Keywords
Funding Information
- Axonics Modulation Technologies
This publication has 18 references indexed in Scilit:
- Sacral Neuromodulation: Standardized Electrode Placement TechniqueNeuromodulation: Technology at the Neural Interface, 2017
- Clinical correlates of faecal incontinence in systemic sclerosis: identifying therapeutic avenuesRheumatology, 2016
- Cost profiles and budget impact of rechargeable versus non‐rechargeable sacral neuromodulation devices in the treatment of overactive bladder syndromeNeurourology and Urodynamics, 2016
- Results of a prospective, multicenter study evaluating quality of life, safety, and efficacy of sacral neuromodulation at twelve months in subjects with symptoms of overactive bladderNeurourology and Urodynamics, 2014
- Rechargeable occipital nerve stimulator systems: A patient satisfaction studyBritish Journal Of Neurosurgery, 2014
- Global Prevalence and Economic Burden of Urgency Urinary Incontinence: A Systematic ReviewEuropean Urology, 2014
- Rechargeable Deep Brain Stimulation Implantable Pulse Generators in Movement Disorders: Patient Satisfaction and Conversion ParametersNeuromodulation: Technology at the Neural Interface, 2013
- Randomized prospective crossover study of interstim lead wire placement with curved versus straight styletNeurourology and Urodynamics, 2013
- Rechargeable Internal Neural Stimulators—Is There a Problem with Efficacy?Neuromodulation: Technology at the Neural Interface, 2011
- Worldwide prevalence estimates of lower urinary tract symptoms, overactive bladder, urinary incontinence and bladder outlet obstructionBJU International, 2011