Accurate Fault Detection of Distribution Network with Optimal Placement of Phasor Measurement Unit
Authors:
- 1 February 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 76-81
Abstract
With increasing power system complexities, fault becomes more common which makes the equipments and workers exposed to catastrophes. Previously supervisory control and data acquisition(SCADA) system were used to monitor and detect fault in power system, but it's lower sampling rate makes it inappropriate to use. This paper presents an improved approach for fault detection in distribution line. The proposed method uses Phasor Measurement Units (PMU)to detect fault quickly and operate the circuit breakers(CB) to ensure system stability and security. For this purpose 30 kW generating station feeding power to 10 km distribution line with a step up transformer (208/11 kV) and a 24 kW solar photovoltaic(PV)module is used here. PMU's are installed at synchronous generator, PV grid, and load buses respectively. The data from the PMU are aligned and planned to IEEE C37.118 format before transmitted to the Phasor data concentrator. Here, positive sequence phase locked loop (PLL) based PMU is used to measure the power system parameters like voltage, frequency, and phase respectively. The large deviation in any parameter can be used to trigger the CB. Quick and Accurate fault detection in the distribution network eliminates any big catastrophic effect and saves from monetary loss. The performance of the proposed model can be evaluated by calculating Total Vector Error of the PMU and then comparing it with IEEE C37.118 standards. Proposed scheme also provides optimal placement of PMU in the given system.Keywords
This publication has 10 references indexed in Scilit:
- Modeling of Phasor Measurement Unit for Wide Area Monitoring and control of Smart Grids with Distributed Energy Resources2016
- A software development toolkit for real-time synchrophasor applications2013
- A Survey on Smart Grid Potential Applications and Communication RequirementsIEEE Transactions on Industrial Informatics, 2012
- An Adaptive Method for Detection and Correction of Errors in PMU MeasurementsIEEE Transactions on Smart Grid, 2012
- Synchronized Phasor Measurement Applications in Power SystemsIEEE Transactions on Smart Grid, 2010
- Synchrophasor-based power system protection and control applications2010
- Wide area system monitoring and controlIEEE Power and Energy Magazine, 2004
- Communications technology guidelines for EMS/SCADA systemsIEEE Transactions on Power Delivery, 2001
- Power system observability with minimal phasor measurement placementIEEE Transactions on Power Systems, 1993
- A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of FrequencyIEEE Transactions on Power Apparatus and Systems, 1983