Novel Experimental Setup for Ascending Thoracic Aortic Aneurysm Inflation Testing
Authors:
- Hugo Mesquita VasconcelosHVHugo Mesquita Vasconcelos
- Daniela AzevedoDADaniela Azevedo
- Rodrigo ValenteRodrigo Valente
- Pedro J. SousaPedro J. Sousa
- Tiago DominguesTDTiago Domingues
- Susana DiasSDSusana Dias
- Rogério F. F. LopesRLRogério F. F. Lopes
- Gonçalo P. CiprianoGCGonçalo P. Cipriano
- António TomásATAntónio Tomás
- Paulo J. TavaresPTPaulo J. Tavares
- José XavierJosé Xavier
- Pedro M. G. P. MoreiraPMPedro M. G. P. Moreira
Open Access
- 10 February 2026
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 13 (2) , 199
Abstract
Degraded mechanical properties in the aortic wall can lead to the formation of aortic aneurysms, potentially resulting in life-threatening ruptures. Current diagnostic criteria using maximum aortic diameter often fail to predict this critical moment, underscoring the need for more accurate patient-based prediction methods. A hospital-compatible experimental apparatus was designed for quasi-static ex vivo inflation testing of intact Ascending Thoracic Aortic Aneurysm (ATAA) specimens with 360° full-field three-dimensional digital image correlation (3D-DIC). Given hospital handling constraints, liquid pressurization was not feasible; instead, pressure was applied via a balloon-driven pneumatic system, and synchronized stereo imaging was used to measure surface displacement fields between 80 and 120 mmHg. The system was validated using a CT-derived ATAA silicone phantom. Full-field displacement measurements showed close agreement with finite element simulations, supporting the mechanical reliability of the apparatus and the repeatability of the measurement workflow. In addition, a frozen–thawed healthy porcine thoracic aorta was tested to demonstrate biological feasibility, particularly regarding the speckle application and DIC tracking, without aiming to extract tissue constitutive parameters. Overall, the setup provides a practical framework for acquiring full-field inflation-induced deformation data from intact aortic specimens in a hospital setting, enabling future studies on resected human ATAA tissue and model calibration that may contribute to more accurate methods for rupture prediction.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (PTDC/EMD-EMD/1230/2021)
This publication has 25 references indexed in Scilit:
- Multi-view Digital Image Correlation Systems for In Vitro Testing of Arteries from Mice to HumansExperimental Mechanics, 2021
- Biomechanics of Blood Vessels: Structure, Mechanics, and Adaptation2015
- In vitro analysis of localized aneurysm ruptureJournal of Biomechanics, 2014
- Temporal trends in sudden unexpected death in a general population: The Hisayama StudyAmerican Heart Journal, 2013
- Mechanical characterization of human aortas from pressurization testing and a paradigm shift for circumferential residual stressJournal of the Mechanical Behavior of Biomedical Materials, 2013
- Essential Cardiology2013
- Circumferential variations of mechanical behavior of the porcine thoracic aorta during the inflation testJournal of Biomechanics, 2011
- Linear and Nonlinear Viscoelastic Modeling of Aorta and Carotid Pressure–Area Dynamics Under In Vivo and Ex Vivo ConditionsAnnals of Biomedical Engineering, 2011
- Elastic and Rupture Properties of Porcine Aortic Tissue Measured Using Inflation TestingCardiovascular Engineering, 2006
- Failure properties of passive human aortic tissue. II—Biaxial tension testsJournal of Biomechanics, 1983