Outcomes Associated With Extraction Versus Capping and Abandoning Pacing and Defibrillator Leads
- 10 October 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 136 (15) , 1387-1395
Abstract
Background: Lead management is an increasingly important aspect of care in patients with cardiac implantable electronic devices; however, relatively little is known about long-term outcomes after capping and abandoning leads. Methods: Using the 5% Medicare sample, we identified patients with de novo cardiac implantable electronic device implantations between January 1, 2000, and December 31, 2013, and with a subsequent lead addition or extraction ≥12 months after the de novo implantation. Patients who underwent extraction for infection were excluded. Using multivariable Cox proportional hazards models, we compared cumulative incidence of all-cause mortality, device-related infection, device revision, and lead extraction at 1 and 5 years for the extraction versus the cap and abandon group. Results: Among 6859 patients, 1113 (16.2%) underwent extraction, whereas 5746 (83.8%) underwent capping and abandonment. Extraction patients tended to be younger (median, 78 versus 79 years; P P =0.05), and had shorter lead dwell time (median, 3.0 versus 4.0 years; P P =0.027). There was no association between extraction and mortality, lead revision, or lead extraction at 5 years. Conclusions: Elective lead extraction for noninfectious indications had similar long-term survival to that for capping and abandoning leads in a Medicare population. However, extraction was associated with lower risk of device infections at 5 years.Keywords
This publication has 26 references indexed in Scilit:
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Review of the Registry's Fourth Year, Incorporating Lead Data and Pediatric ICD Procedures, and Use as a National Performance MeasureHeart Rhythm, 2010
- Lead Extraction Is Preferred for Lead Revisions and System Upgrades: When Less Is MoreCirculation: Arrhythmia and Electrophysiology, 2010
- Lead Extraction in the Contemporary Setting: The LExICon StudyJACC, 2010
- Do abandoned leads pose risk to implantable cardioverter-defibrillator patients?Heart Rhythm, 2009
- Necessity for Surgical Revision of Defibrillator Leads Implanted Long-TermCirculation, 2008