Frequency-tunable micromechanical oscillator
Authors:
- 13 November 2000
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 77 (20) , 3287-3289
Abstract
An experimental method, employing a scanning tunneling microscope (STM) as an actuator and a scanning electron microscope (SEM) as a motion detector, was developed to study microelectromechanical systems (MEMS) and has been applied to study microfabricated cantilever beams. Vibrations actuated by an ac voltage applied to the piezodrive are transferred to the sample by the STM tip, which also provides a constraint at the drive location, altering the fundamental mode of the oscillation. A continuous change in the resonant frequency of the cantilever is achieved by varying the position of the STM tip. In contrast to the few percent tunability previously demonstrated for MEMS oscillators, we have varied the cantilever frequency over a 300% range.Keywords
This publication has 7 references indexed in Scilit:
- Mechanical resonant immunospecific biological detectorApplied Physics Letters, 2000
- Nanofabrication and electrostatic operation of single-crystal silicon paddle oscillatorsJournal of Applied Physics, 1999
- Torsion cantilever as magnetic torque sensorReview of Scientific Instruments, 1998
- Cantilever magnetometry in pulsed magnetic fieldsReview of Scientific Instruments, 1997
- Attonewton force detection using ultrathin silicon cantileversApplied Physics Letters, 1997
- Magnetic resonance force microscopyReviews of Modern Physics, 1995
- Mechanical detection of magnetic resonanceNature, 1992