SHM of a Tall Building
Authors:
- 26 January 2008
- book chapter
- Published by Wiley
Abstract
A long‐term monitoring program on a 280‐m 65‐story office tower began in 1993 when Shimizu Corporation installed stress and strain gauges at the 18th story during construction. Manual static readings were combined with measurements of fundamental mode natural frequencies, and when the building was completed, a full vibration survey was undertaken, after which a remotely operated monitoring system was installed to track wind velocities along with accelerations at basement and roof levels. The system operated for 10 years, and in its final years global positioning system (GPS) receivers for tracking “absolute” displacements were included. The monitoring system showed gradual changes in building performance over time, but more importantly it provided valuable information about the nature of the dynamic loading experienced due to wind and earthquake. Using the building as a super sensor showed the significance of regional seismic hazard in comparison to the benign wind loading. The system also provided a platform for evaluating structural health monitoring technology including GPS, operational modal analysis, and data mining.Keywords
This publication has 7 references indexed in Scilit:
- Validating Wind-Induced Response of Tall Buildings: Synopsis of the Chicago Full-Scale Monitoring ProgramJournal of Structural Engineering, 2006
- Lateral loading and response for a tall building in the non-seismic doldrumsEngineering Structures, 2005
- Response of tall buildings to weak long distance earthquakesEarthquake Engineering & Structural Dynamics, 2001
- Correlating dynamic characteristics from field measurements and numerical analysis of a high-rise buildingEarthquake Engineering & Structural Dynamics, 2000
- Full-Scale Dynamic Response of High-Rise Building to Lateral LoadingJournal of Performance of Constructed Facilities, 1998
- EXPERIMENTAL MONITORING OF THE HUMBER BRIDGE USING GPS.Civil Engineering, 1997
- Interim findings from full-scale measurements at Hume PointJournal of Wind Engineering and Industrial Aerodynamics, 1990