Suppression of Peptide Sample Losses in Autosampler Vials
- 1 May 2013
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 12 (6) , 3057-3062
Abstract
Protein or peptide sample losses could accompany all steps of the proteomic analysis workflow. We focused on suppression of sample adsorptive losses during sample storage in autosampler vials. We examined suppression capabilities of six different sample injection solutions and seven types of autosampler vial surfaces using a model sample (tryptic digest of six proteins, 1 fmol per protein). While the vial material did not play an essential role, the choice of appropriate composition of sample injection solution reduced adsorptive losses substantially. The combination of a polypropylene vial and solution of poly(ethylene glycol) (PEG) (0.001%) or a mixture of high concentrated urea and thiourea (6 M and 1 M) as injection solutions (both acidified with formic acid (FA) (0.1%)) provided the best results in terms of number of significantly identified peptides (p < 0.05). These conclusions were confirmed by analyses of a real sample with intermediate complexity (in-gel digest from sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE)). Addition of PEG into the real sample solution proved to prevent higher losses, concerning mainly hydrophobic peptides, during up to 48 h storage in the autosampler in comparison with a formic acid solution and even with a solution of highly concentrated urea and thiourea. Using PEG for several months was not accompanied by any adverse effect to the liquid chromatography system.Keywords
This publication has 18 references indexed in Scilit:
- The importance of using the optimal plasticware and glassware in studies involving peptidesAnalytical Biochemistry, 2011
- Evaluation of apparent non-specific protein loss due to adsorption on sample tube surfaces and/or altered immunogenicityThe Analyst, 2011
- Mass spectrometry analysis of soybean seed proteins: optimization of gel-free quantitative workflowAnalytical Methods, 2010
- Comparison between a linear ion trap and a triple quadruple MS in the sensitive detection of large peptides at femtomole amounts on columnJournal of Separation Science, 2010
- Optimization of digestion parameters for protein quantificationAnalytical Biochemistry, 2009
- Differential Recovery of Peptides from Sample Tubes and the Reproducibility of Quantitative Proteomic DataJournal of Proteome Research, 2007
- A Tandem Affinity Purification-based Technology Platform to Study the Cell Cycle Interactome in Arabidopsis thalianaMolecular & Cellular Proteomics, 2007
- Development of packed capillary columns using carbon dioxide slurriesJournal of Separation Science, 2003
- Unbiased quantitative proteomics of lipid rafts reveals high specificity for signaling factorsProceedings of the National Academy of Sciences of the United States of America, 2003
- Effects of adsorption to plastics and solvent conditions in the analysis of the cyanobacterial toxin microcystin-LR by high performance liquid chromatographyWater Research, 2001