Optically Probing the Chirality of Single Plasmonic Nanostructures and of Single Molecules: Potential and Obstacles
Open Access
- 20 October 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 9 (11) , 3486-3497
Abstract
Circular dichroism (CD) is a standard method for the analysis of biomolecular conformation. It is very reliable when applied to molecules, but requires relatively large amounts of solution. Plasmonics offer the perspective of enhancement of CD signals, which would extend CD spectrometry to smaller amounts of molecules and to weaker chiral signals. However, plasmonic enhancement comes at the cost of additional complications: averaging over all orientations is no longer possible or reliable, linear dichroism leaks into CD signals because of experimental imperfections, scattering and its interference with the incident beam must be taken into account, and the interaction between chiral molecules and possibly chiral plasmonic structures considerably complicates the interpretation of measured signals. This Perspective aims to explore the motivations and problems of plasmonic chirality and to re-evaluate present and future solutions.Keywords
Funding Information
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (16008)
This publication has 93 references indexed in Scilit:
- Attomolar DNA detection with chiral nanorod assembliesNature Communications, 2013
- Two-Photon Polarization Dependent Spectroscopy in Chirality: A Novel Experimental-Theoretical Approach to Study Optically Active SystemsMolecules, 2011
- Using circular dichroism spectra to estimate protein secondary structureNature Protocols, 2006
- Calculated Absorption and Scattering Properties of Gold Nanoparticles of Different Size, Shape, and Composition: Applications in Biological Imaging and BiomedicineThe Journal of Physical Chemistry B, 2006
- Kramers−Kronig Transformation for Optical Rotatory Dispersion StudiesThe Journal of Physical Chemistry A, 2005
- A Hausdorff chirality measureJournal of the American Chemical Society, 1992
- On the Problems of CD Spectropolarimeters. II: Artifacts in CD SpectrometersApplied Spectroscopy, 1985
- On the Problems of CD Spectropolarimeter (IV) Artifacts Due to the Light Scattering by Small ParticlesApplied Spectroscopy, 1985
- Circular dichroism measurements. I. Calibration of a circular dichroism spectrometerReview of Scientific Instruments, 1985
- Circular dichroism and optical rotationChemical Reviews, 1975