Performance evaluation of x‐ray differential phase contrast computed tomography (PCT) with respect to medical imaging
Authors:
- 19 July 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (8) , 4761-4774
Abstract
Purpose: To evaluate the maximum performance gain that can theoretically be achieved with differential phase contrast computed tomography (PCT) compared with absorption‐based CT, applied toin vivo medical imaging.Methods: We develop a mathematical framework for analyzing the performance of PCT relative to CT under ideal conditions. We validate our model by interpreting the results of published PCT experiments. Finally, we utilize our framework to evaluate the relative performance of PCT versus CT forin vivo medical imaging of the human body, investigating several clinically relevant material contrasts.Results: : We show that the performance of PCT relative to CT depends on the ratio of phase contrast and absorption contrast of the examined materials and increases with increasing effective coherence length and increasing spatial resolution. The introduced effective coherence length characterizes an experimental PCT setup; it comprises coherence of the beam as well as properties of the x‐ray interferometer. Whole body medical CT will not benefit from phase‐contrast imaging, because the higher phase contrast is overcompensated by the low coherence lengths of PCT setups with low‐brilliance sources, and by limited spatial resolution. The relative performance of PCT, which is inferior to CT for all examined material contrasts at the resolution level of today's medical CT, can be improved by increasing spatial resolution at the expense of increased patient dose. At the break‐even point of equal performance for PCT and CT, a radiation dose at least 1 order of magnitude higher than today is required. Mammographic CT already operates at higher spatial resolution and may benefit from PCT for some applications in terms of reduced patient dose at equal image quality.Conclusions: Phase‐contrast imaging utilizing low‐brilliance x‐ray sources has limited potential for an application in routine whole body CT. Breast CT, however, may benefit from phase‐contrast imaging. These conclusions are due to fundamental arguments and independent of whether technical issues (quality of gratings, etc.) can be solved. PCT will only be suitable forin vivo medical imaging if x‐ray sources with much better spatial coherence are routinely available.Keywords
This publication has 33 references indexed in Scilit:
- Noise properties of grating-based x-ray phase contrast computed tomographyMedical Physics, 2011
- Noise in x‐ray grating‐based phase‐contrast imagingMedical Physics, 2011
- Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomographyPhysics in Medicine & Biology, 2011
- Scaling law for noise variance and spatial resolution in differential phase contrast computed tomographyMedical Physics, 2011
- Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patientsEuropean Radiology, 2010
- Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CTMedical Physics, 2010
- Noise texture and signal detectability in propagation‐based x‐ray phase‐contrast tomographyMedical Physics, 2009
- Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube sourceOptics Express, 2009
- Patient Exposure and Image Quality of Low-Dose Pulmonary Computed Tomography AngiographyInvestigative Radiology, 2008
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006