Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis
Authors:
- Max PotratzMPMax Potratz
- Kawa MohemedKMKawa Mohemed
- Hazem OmranHOHazem Omran
- Lasha GortamashviliLGLasha Gortamashvili
- Kai Peter FriedrichsKFKai Peter Friedrichs
- Werner ScholtzWSWerner Scholtz
- Smita ScholtzSSSmita Scholtz
- Volker RudolphVRVolker Rudolph
- Cornelia PiperCPCornelia Piper
- Tomasz Gilis-JanuszewskiTGTomasz Gilis-Januszewski
- René SchrammRSRené Schramm
- Nobuyuki FurukawaNFNobuyuki Furukawa
Open Access
- 5 August 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4570
Abstract
Background: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. Methods: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. Results: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. Conclusions: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.Keywords
Funding Information
- DFG Open Access Publication Funds of the Ruhr-Universität Bochum
This publication has 54 references indexed in Scilit:
- Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve ReplacementCirculation, 2013
- Impact of aortic valve calcification on the outcome of transcatheter aortic valve implantation: Results from the prospective multicenter German TAVI registryCatheterization and Cardiovascular Interventions, 2012
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- The impact of prosthesis–patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-yearsEuropean Heart Journal, 2012
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- “Device landing zone” calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVICatheterization and Cardiovascular Interventions, 2010
- Prosthesis–Patient Mismatch After Transcatheter Aortic Valve Implantation With the Medtronic CoreValve System in Patients With Aortic StenosisThe American Journal of Cardiology, 2010
- Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve ProsthesisJACC: Cardiovascular Interventions, 2010
- Constructing a Control Group Using Multivariate Matched Sampling Methods That Incorporate the Propensity ScoreThe American Statistician, 1985
- The problem of valve prosthesis-patient mismatch.Circulation, 1978